Lighting Pilot Burner

These griddles are fitted with a pilot as a standard option and flame failure protection, which is
incorporated for each main burner, by way of a thermo-electric system. Flame failure protection will shut
off gas supply to that burner in the event that pilot burner goes out, so that un-burnt gas is not expelled.
This is an important safety feature which is slowly becoming law throughout the world
1.
Partially depress gas control knob whilst turning knob
anti-clockwise to 'Pilot' position. DO NOT fully
depress Gas Control Knob whilst trying to
rotate anti-clockwise as Knob and Gas Valve
will be damaged.
2.
With gas control knob in 'Pilot' position, keep knob
depressed whilst pressing piezo igniter button. (Each
press of piezo igniter button will generate a single
spark).
3.
Hold gas control knob depressed for approx. 10-15
seconds, then release. Pilot burner should remain
alight. (If pilot does not light, repeat Items 1 to 3
above).
4.
Pilot ignition can be viewed through opening in plastic
surround of piezo igniter button.
NOTE: If pilot burner goes out during normal operation
wait 5 minutes before re-lighting.

Lighting Main Burner

1.
Ensure pilot burner is alight.
2.
Rotate gas control knob anti-clockwise to desired
temperature marked on knob.
3.
Main burner will ignite automatically, from pilot
burner.

Turning 'Off' Main Burner / Pilot

NOTE: DO NOT attempt to rotate Gas Control Knob anti
-clockwise back to the 'O', Off position as Knob
and Gas Valve will be damaged.
1.
Rotate gas control knob clockwise to 'Pilot' position.
Main burner will extinguish and pilot burner will
remain alight.
2.
To turn 'Off' main burner completely,
depress
gas control knob whilst turning clockwise to
Off position, pilot burner will extinguish. DO NOT
fully depress Gas Control Knob whilst trying to
rotate clockwise to Off position as Knob and
Gas Valve will be damaged.
Depress and Rotate Anti-Clockwise to Pilot Position
Rotate Anti-Clockwise to Operating Temperature
partially
Rotate Clockwise to Pilot Position - Then Partially
13
Operation
Pilot Flame
Viewing Opening
Piezo Igniter Button
Control Knob in Main
Burner Operating Position
Depress and Rotate to 'O' - Off Position.
.
Control Knob in
Pilot Position
Control Knob in
Pilot Position

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evolution gp518Evolution gp516

Table of Contents