Gas Regulator - Blue Seal Evolution GP514 Installation And Operation Manual

Evolution series gas griddle
Table of Contents

Advertisement

Gas Conversion and Specifications

Gas Regulator

NOTE: Gas
regulator
convertible between Natural Gas
and LP Gas, but it's outlet
pressure is fixed ex-factory and
is NOT to be adjusted.
- Town Gas Only.
1.
Remove slotted cap from regulator.
2.
Turn 'On' gas supply and appliance.
3.
Adjust pressure adjusting screw to achieve correct burner
operating pressure.
NOTE: Operating pressure to be measured at manifold test
point with one burner operating at 'High Flame' setting.
4.
Turn 'Off' mains gas supply and bleed gas out of appliance gas
lines.
5.
Turn 'On' gas supply and appliance.
6.
Verify operating pressure remains correct (Re-adjust regulator
if required).
7.
Screw cap nut back onto regulator.
Gas Type Labels
On completion of gas conversion, replace gas type labels located at:-
- Rear of unit, above gas connection.
- Beside rating plate.
Commissioning
Before leaving installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a 'Commissioning' check of appliance as shown in Installation Section of this manual.
3.
Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut 'Off' gas
supply and contact supplier of this appliance.
supplied
is
Warning
D
O NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES
20
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Cap Nut
Pressure Adjusting
Screw
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evolution gp518Evolution gp516

Table of Contents