Short code
Full-text message
PSER
PAN SENSOR ERROR
Unable to detect pan position sensor calibration data.
PTCM
P/T SENSOR CAL
Unable to detect pan/tilt sensor calibration data.
PTCO
PU TMP CUTOFF
Ballast shut down because temperature is too high (thermal cutoff).
PTSE
PU TMP SEN ERR
A ballast temperature sensor is not communicating normally. Fans set to full speed.
RFER
RIGHT FROST ERROR
Right-side frost/wash effect position indexing system error. Fixture will work normally but frost filter
may lose position and hit mechanical stop.
SHER
SHORT ERROR
Short circuit error.
SHUE
SHUTTER ERROR
Shutter position indexing system error. Fixture will work normally but shutter may lose position and
hit mechanical stop.
SLER
SAFETY LOOP ERROR
Lamp safety loop circuit activated: lamp access hatch is open or lamp thermal cutoff activated.
SSTO
SYSTEM STATE TIMEOUT
Failure to communicate with module during self-check at startup. Service intervention required.
Fixture control possibly disabled, depending on nature of error.
TIER
TILT ERROR
Tilt alignment circuit error.
TSER
TILT SENSOR ERROR
Unable to detect tilt position sensor calibration data.
UECH
UPL ERR CHARGER
Could not upload new firmware to charger module.
UECM
UPL ERR CMY
Could not upload new firmware to CMY module.
UECO
UPL ERR COOLING
Could not upload new firmware to cooling module.
UEEF
UPL ERR EFFECT
Could not upload new firmware to effects module.
UEPT
UPL ERR PAN/TILT
Could not upload new firmware to pan/tilt module.
UEPU
UPL ERR PU
Could not upload new firmware to ballast module.
UEUI
UPL ERR UI
Could not upload new firmware to user interface module.
UEZF
UPL ERR Z/F
Could not upload new firmware to zoom/focus module.
UPLD
DMX UPLOAD ERROR
An error occurred during a firmware upload via the DMX data input. Check cabling and connections,
and then restart.
YEER
YELLOW ERROR
Yellow position indexing system error. Fixture will work normally but yellow flags may lose position
and hit mechanical stop.
YTCO
YOKE TMP CUT OFF
A yoke temperature sensor has reported a temperature above the permitted maximum for more
than 5 minutes. Lamp shut down. A fan may be defective or the ambient temperature may be too
high.
YTSE
YOKE TMP SEN ERR
A yoke temperature sensor is not communicating normally. Fans set to full speed.
ZOER
ZOOM ERROR
Zoom position indexing system error. Fixture will work normally but zoom may lose position and hit
mechanical stop.
Table 5: Error messages