Warning messages
Short code
AIRS
BANK
BATM
BT W
DINA
EEPR
FTNA
FUSB
HOT
HT W
INLK
LTIM
MALW
PANA
SHNA
TINA
YT W
* Adjustment should only be carried out by a qualified service technician with Martin™ service
documentation.
** High temperature warnings are canceled as soon as temperature returns to normal. If temperature
reaches cutoff level, the warning is replaced by a cutoff error message.
54
Full-text message
CHECK AIR FILTERS
The timer available in the SERVICE menu has reached the point for which the alarm was set.
BANK NO ACCESS
Error unpacking firmware bank during/after software upload. Fixture will continue to operate on
existing firmware. Warning message is cleared by a successful software upload or at the next
power off/on cycle.
BATTERY MODE
Switched to battery power source with limited functionality. Plug in power cable to restore full
function operation.
BASE TEMP HIGH
At least one base PCB indicates temperature within 10% of maximum**.
DIMMER NOT ADJUSTED
No dimmer adjustment data in EEPROM. Dimmer may be incorrectly adjusted*.
EEPROM INVALID
No connection or EEPROM data invalid.
FROST NOT ADJUSTED
No frost/wash effect adjustment data in EEPROM. Wash effect may be incorrectly adjusted*.
USB UPLOAD
The fixture has been started in forced USB upload mode (the Escape button was held during
power up).
LAMP HOT
Lamp strike fails. Pan and tilt are disabled temporarily to reduce the risk of falling fragments if the
lamp has exploded. Fixture will try to restrike lamp three times ar 20 second intervals. If lamp still
refuses to strike after three attempts, an LAER (Lamp Error) message is displayed.
HEAD TEMP HIGH
One or more of the PCB's in the head is within 10% of maximum**.
INVALID LICENSE KEY
Invalid license key entered. Warning is displayed and it is impossible to enter a license key for 10
seconds.
LAMP LIFETIME
Lamp life is within 10% of limit set in LAMP ON TIME → SET TIME ALERT in the control panel
menu or via RDM.
MAINS LOW
Mains voltage is below acceptable level. The lamp may not be able to strike (if impossible to strike,
MALE error appears).
PAN NOT ADJUSTED
No pan adjustment data in EEPROM. Pan may be incorrectly adjusted*.
SHUTTER NOT ADJUSTED
No shutter adjustment data in EEPROM. Shutter may be incorrectly adjusted*.
TILT NOT ADJUSTED
No tilt adjustment data in EEPROM. Tilt may be incorrectly adjusted*.
YOKE TEMP HIGH
One or more of the PCB's in the yoke is within 10% of maximum**.
Table 4: Warning messages