Installation (for qualified installers only)

Top Convection Deflector

Install the top convection deflector as
shown to the right.
The deflector is shipped on top of the
insert. The screws are shipped inside
the owner's pack.

Fireplace Requirements

Insert must be placed within a code-conforming masonry fireplace or tested and listed factory-built
(metal) wood-burning fireplace. Repair any fireplace damage prior to installation.
Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior to
installation.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
Min. 19-1/2"
The gas line and shutoff
valve should be installed
prior to insert placement.
© Travis Industries
For tight fits (under 24") see the section "Removing the
Vent Connector"
Min. 26-1/2" - additional space may be required for gas line installation.
Attach the "This fireplace has been altered..." plate
to the fireplace (use two screws or other suitable
method). You may wish to place it in a location
where it will be covered by the surround panels.
4090812
The DVS inserts 15-1/8" into the
fireplace.
See "Leveling Bolts" for details
on leveling the heater.
100-01232_001