INSTALLATION

Electrical Connection

Mains Supply
It is required that all units be connected to the
mains supply through an independent circuit,
suitably protected by fuse or circuit breaker.
Ensure that the power supply is sufficient for the
rating indicated on the serial plate. Wire the unit in
accordance with all state and local regulations.
NOTE
Mains cable must be double insulated if both
mains and control cables are run in the same
c o n d u i t . P l e a s e e n s u r e t h a t t h e h o l e i n t h e
reservoir and any penetration through the roof are
adequately sealed with an approved sealant.
Control Circuit Wiring
Variable Speed - 20 metre Low Voltage cable
supplied with cooler.
Two Speed - Control circuit wiring is via a 240V
5 wire system. (not supplied)
Cooler Controls
Variable Speed - Braemar wall control with
Auto/Manual
Two Speed - 240V Clipsal switch plate pattern.
Cooler Control Location
Variable Speed - It is advisable to locate the controller about 1.5 metres above
the floor level in the room that will be lived in most. Avoid positioning the control in
direct sunlight, an outside wall or near any heat source ( refrigerator etc. ), do not
position in direct line with a cooling outlet. Placing the controller near a heat source
or cooling outlet will effect its temperature readings.
Two Speed - Place the control switch in a room or area that is the most
convenient for you.