OWNER'S MANUAL
HIGH WALL INVERTER
(English) (MSHVD1S SERIES)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSHV25D1S and is the answer not in the manual?

Questions and answers

Stuart McLachlan
May 8, 2025

I have 2 units. One unit stopped working. Replaced batts in faulty remote. Both remotes will activate the other unit. Neither remotes will activate the unit not working. Does the MSHV25D1S have a manual operating switch? Cut out switch checked and turned on. External power switch is on. Does not illuminate the power indicator light on wall unit. Is there something I've missed here? Unit has done very little work, and just didn't turn on. Found remote batts flat. Just has not worked since, even though the same remote works fine on the other unit.

1 comments:
Mr. Anderson
May 19, 2025

The provided context does not mention a manual operating switch for the Braemar MSHV25D1S unit. A possible reason the unit may not turn on, despite the remote working on another unit, could be compressor protection, which prevents the compressor from restarting for 3 minutes after it stops. Another reason could be battery or signal issues with the remote, but this is not explicitly detailed in the context.

Therefore, the unit may not turn on due to compressor protection, but there is no mention of a manual operating switch.

Answer: The unit may not turn on due to compressor protection delay; no manual operating switch is mentioned.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Braemar MSHV25D1S

  • Page 1 OWNER’S MANUAL HIGH WALL INVERTER (English) (MSHVD1S SERIES)
  • Page 2 Warranty terms are subject to property access and industry safety standards.) INDOOR MODEL OUTDOOR MODEL CAPACITY COOL / HEAT SINGLE SPLIT MULTI SPLIT MSHV25D1S SCHV25D1S MCHV54D12 MCHV54D12 2.6 kW / 3.0 kW MSHV35D1S SCHV35D1S MCHV73D13 3.5 kW / 4.0 kW...
  • Page 3: Table Of Contents

    CONTENTS MAIN COMPONENTS..................2 INTRODUCTION & SAFETY ................3 OPERATION REMOTE CONTROLLER................4 CONTROLLER LAYOUT................5 ON/OFF ......................5 MODE ......................5 FAN SPEED....................6 CLOCK ......................6 TEMP ......................6 ......................6 ▲ ▼ X-FAN ......................6 TURBO ......................6 LIGHT ......................6 QUIET ......................7 TIMER SETTINGS..................7 SWING UP / DOWN, LEFT / RIGHT .............7 I FEEL......................8 SLEEP ......................8-9 LOCK FUNCTION ..................9...
  • Page 4: Main Components

    MAIN COMPONENTS INDOOR UNIT cooling power receiver indicator indicator window heating temp. drying indicator indicator indicator 1. Air inlet NOTE: Display panel style or position 2. Front panel may differ from the above graphics. 3. Aux. button 4. Filter 5. Horizontal Louvre 6.
  • Page 5: Introduction & Safety

    SUBSTANTIAL FINES. Warranty Booklet. WHERE SPECIFIED, ONLY The installer must read the Installation QUALIFIED AND LICENSED Manual before installing the Braemar TECHNICIANS SHOULD PERFORM High Wall Inverter Air Conditioning WORK ON THIS UNIT, FAILING Unit. The home owner/user should WHICH THE WARRANTY ON THE read the Owner's Manual before UNIT WILL BE VOID.
  • Page 6: Operation

    OPERATION Your Braemar High Wall Air CHANGING BATTERIES Conditioning Unit has been designed Push down on the battery panel to and built with reliable, quality open the battery compartment area. components. To ensure many years of trouble free, dependable service Insert 2 x AAA 1.5V batteries, ensuring...
  • Page 7: Controller Layout

    OPERATION cont. CONTROLLER LAYOUT Signal transmitter MODE button FAN button SWING L / R button ON/OFF button TURBO button buttons ▲ ▼ SWING UP / I FEEL button DOWN button TIMER ON / OFF buttons SLEEP button QUIET button CLOCK button LIGHT button TEMP HEALTHY...
  • Page 8: Fan Speed

    OPERATION cont. FAN SPEED BUTTONS ▲ ▼ Press the FAN button to toggle Use to adjust the SET temperature between AUTO, Low, Medium-Low, within the range 16-30°C (61-86°F). Medium, Medium-High and High Hold the button down for quick speed. adjustment. Note: TEMP adjustment is unavailable in AUTO mode.
  • Page 9: Quiet

    OPERATION cont. QUIET TIMER OFF cont. QUIET function can be employed to controller display. Use the ▲ ▼ use lower fan speeds to attain the SET buttons to adjust the clock time for the temperature when in AUTO, COOL unit to stop. Holding these buttons and HEAT modes.
  • Page 10: I Feel

    OPERATION cont. SLEEP cont. I FEEL has elapsed. It will then be decreased Press the I FEEL button to activate this by 1°C, then will continue to run at this feature. The remote controller will act temperature. as the temperature thermostat, sending a temperature reading to the b) If SET between 24-27°C, SET unit every 10 minutes.
  • Page 11: Lock Function

    OPERATION cont. SLEEP cont. LOCK d) If SET between 28-30°C, SET The remote controller can be locked temperature will decrease by 1°C for 3 from inadvertent button operation. hours, then will continue to run at this Press both ▲ buttons ▼...
  • Page 12: Error Display

    OPERATION cont. ERROR DISPLAY Your High Wall air conditioner includes abnormal operation detection hardware and software. If the unit enters an abnormal state, the temperature indicator on the fascia display will blink to display a corresponding error code. Indoor display Error code (example only) Error codes and their meanings are shown below: Error Code...
  • Page 13: Maintenance & Service

    MAINTENANCE & SERVICE SAFETY INDOOR COIL (REFER PAGE 2) Ensure drain connections are checked Always isolate power for the air on an annual basis (as set out in the conditioner from electricity mains Maintenance Schedule below). Drains before cleaning or maintenance. can become blocked by all types of insects, and rats have been known to AIR FILTER...
  • Page 14: Maintenance Schedule

    Braemar High Wall Inverter Air Conditioning Unit as per the items and frequency set out in the Schedule, and as indicated elsewhere in this Manual.
  • Page 15: Operation Tips

    OPERATION TIPS The following events may occur during normal operation: 1. Protection of the air conditioner. Compressor protection • The compressor cannot restart for 3 minutes after it stops. • The supply air drops below a pre-determined set point; this prevents the indoor coil from freezing.
  • Page 16: Troubleshooting

    TROUBLESHOOTING Problem Probable Cause Remedy 1. The air conditioner 1.1 Power failure. 1.1 Wait for power to resume. does not run. 1.2 Fuse blown or circuit 1.2 Replace the fuse or reset breaker open. the breaker. 1.3 Thermostat adjustment 1.3 Check thermostat setting. too low (in heating mode) In ‘I FEEL’...
  • Page 17: Warranty & Service

    WARRANTY & SERVICE For prompt, efficient service, please follow the above before calling the appropriate number below. For Refrigerated Cooling Issues 1300 526 477 When calling the Warranty Service number, please ensure you have your model and serial number available, along with date of purchase, and if possible a description of the problem.
  • Page 18 NOTES MSHV Series High Wall Inverter Unit...
  • Page 19 NOTES cont. SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 20 It is the policy of Seeley International to introduce continuous product improvements. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected. Warranty Service Refrigerated Cooling 1300 526 477 seeleyinternational.com 66129917002 braemar.net.au AU 1408 MSHV80D1S01-A...