MTU-M Maintenance Functions
Would you like to modify values? [Y/N]:: Y
You must enter password to modify values: new
The following values have been copied to a work buffer and
individual changes will be made to the variables in the work buffer.
When finished with changes, enter <quit>
and you will be asked if you want the changes saved.
Hit return to continue
6-8
The following table provides a description of the network management options:
Field
Function
IP Address
Contains the IP address of the MTU-M card itself.
Subnet Mask
Contains the Subnet Mask of the MTU-M card.
SNMP Manager
Contains the IP Address of your SNMP Manager.
Address
Default Gateway
Contains the address of the gateway that is to be used to reach
Address
hosts that are not on the same subnet as the MTU-M.
Broadcast Address
Indicates whether or not alarms are automatically displayed
on the system terminal as they occur.
System Contact
Allows you to enter up to 128 ASCII characters. This field is
for informational purposes only.
System Name
Allows you to enter up to 128 ASCII characters. This field is
for informational purposes only.
System Location
Allows you to enter up to 128 ASCII characters. This field is
for informational purposes only.
Change Password
Allows you to change your MTU-M password. The default
password is new.
Menu path: Main
Maintenance
March 1998
netconfig
...
(Screen 2 of 3)
7900-A2-GB20-00