Connecting the Primary Nest to Additional Nests

7900-A2-GB20-00
Connections between nests are only made from the primary nest (Nest 1) to each
expansion nest (Nests 2, 3, and 4). Connecting the primary nest to an expansion
nest allows the MTU-M to monitor the nest card termination units in Nests 2, 3,
and 4.
Procedure
To connect the primary nest to each expansion nest:
1. Connect the primary nest and Nest 2 by connecting the nest expansion cable
between J28 (TO 2) on the primary nest to J26 (FROM 1) on Nest 2.
2. Connect the primary nest and Nest 3 by connecting the nest expansion cable
between J29 (TO 3) on the primary nest to J26 (FROM 1) on Nest 3.
3. Connect the primary nest and Nest 4 by connecting the nest expansion cable
between J27 (TO 4) on the primary nest to J26 (FROM 1) on Nest 4.
Nest 1
(Primary)
P6
TO 4
POWER J27
TO 2
J28
–48vB
Agnd
TO 3
–48vA
J29
FROM 1
J26
Local Loop
TO 4
J27
POWER
TO 2
Bgnd
J28
–48vB
Agnd
TO 3
–48vA
J29
FROM 1
J26
March 1998
POWER
Bgnd
–48vB
P5
Agnd
Alarms
–48vA
RS232
Modem
10BaseT
DB25
AUI
Network
Management
DB15
POWER
Bgnd
–48vB
Agnd
–48vA
POWER
Bgnd
–48vB
Agnd
–48vA
MTU-M Installation Procedures
Nest 2
TO 4
J27
TO 2
J28
TO 3
J29
FROM 1
J26
Nest 3
TO 4
J27
TO 2
J28
TO 3
J29
FROM 1
J26
Nest 4
TO 4
J27
TO 2
J28
TO 3
J29
FROM 1
J26
97-15414
2-3