7900-A2-GB20-00
The following table provides a description of the operations parameters:
Field
EEPROM values are
Polling Range
Polling interval
Polling time-out
Initial alarm on/off
setting
Initial menu on/off
setting
Console port baud rate
Menu path: Main
Maintenance
MTU–M Operations Parameters Menu
Select Command:
COMMAND
max xtu
min xtu
polling interval –
pollto
alarm
menu
console
read
Quit
op param–>
March 1998
Function
Displays the current status of the xTU-C EEPROM values.
Displays the maximum and minimum xTU-C polling address.
The maximum possible xTU-C address is the right-most card
in the lowest nest. Refer to
Sequence
, in Chapter 2, MTU-M Installation Procedures , for
the xTU numbering sequence.
Indicates the amount of time the MTU-M waits between
successive starts of the polling cycle. If all of the nest cards
can not be polled in this amount of time they may be
skipped.
Denotes the maximum amount of time, in 256th seconds,
that the MTU-M will wait between the polling of each line
card.
Indicates whether or not alarms are automatically displayed
on the system terminal as they occur.
Indicates whether or not menus are displayed on the system
terminal.
Indicates the baud rate for the system terminal.
sysconfig (Enter)
DESCRIPTION
–
set the maximum xtu polling address
–
set the minimum xtu polling address
set active circuit polling time interval
–
set polling time-out length
–
change initial alarm on/off setting
–
change initial menu on/off setting
–
set console port baud rate
–
re–read the EEPROM
–
Quit Command
MTU-M Maintenance Functions
Expansion Nest Numbering
6-5