6.
Measure the table bracket to the stand to
assure it is parallel to the stand. See Figure
8. If the bracket is not parallel, remove the
vertical brace, thread the horizontal brace in
or out an appropriate amount and reinstall
the vertical brace.
Figure 8. Checking table bracket for parallelism.
7.
Once the table bracket has been properly
adjusted, tighten the horizontal brace jam
nut and the two hex nuts that hold the verti-
cal brace in place.
8.
Attach the table trunnions to the table brack-
et. Each is held in place with a
er and lock handle. See Figure 9. The trun-
nion with the scale attaches to the left side.
Figure 9. Table trunnions installed.
G1140 Edge Sander
9.
10. Adjust the work table 90˚ to the sanding plat-
3
/
'' flat wash-
8
Leaving the table trunnion lock handles
slightly loose, bolt the working table to the
trunnions using the two (2)
5
bolts and
'' flat washers supplied. See
16
Figure 10. Adjust the table so it is approxi-
1
3
mately
'' to
'' from the edge of the sand-
8
16
ing platen and tighten down the mounting
bolts.
Figure 10. Attaching the working table.
en by checking it with a square. Adjust as
necessary and tighten the table lock han-
dles. At this time adjust the pointer to 90˚.
See Figure 11.
Figure 11. Setting the pointer to 90˚.