At any time, you may check the programming of any aspect of any
skimming/heating cycle by first pressing CYCLE then moving through the
menu by pressing either CYCLE or SELECT. The programming is changed
only by pressing UP or DOWN during this process.

10.3 Programming The Change Filter Reminder

Your new spa is equipped with a programmable "Change
Filter" reminder that appears on the control panel display after
a specified number of days. It is designed to remind you to
clean and/or replace your filter cartridge(s) on a regular basis but does not
affect spa operation in any way. This reminder must be reset at each filter
cleaning interval. It offers a selectable range from 10-120 days or can be
disabled. We recommend an initial setting of 30 days, after which you can
easily determine whether you need to shorten or lengthen its interval by
visually inspecting your filter cartridge. Refer to section 1 1.1 (page 32-33)
for filter cleaning recommendations.
Programming Instructions
(1) Press the CYCLE sensor seven times. The main display reads "FIL"
indicating the "Change Filter" display program has been accessed.
(2) Press SELECT sensor once to display currently programmed duration or
days elapsed since last filter cleaning interval.
(3) Press UP or DOWN sensor to change duration as follows:
0 - 10 - 20 - 30 - 40 - 50 - 60 - 70 - 80 - 90 - 100 - 1 10 - 120 - OFF
(4) Press DISPLAY sensor once to save changes and return to the
standard water temperature display. Note: If no sensor is pressed
within 30 seconds, the screen will automatically return to the standard
water temperature display.

10.4 Programming Circulation Pump Run Time

The Sentry control system allows you to easily adjust two separate aspects
of circulation pump operation:
1. The time of day (start time) the circulation pump turns on.
2. The length of time (duration) the circulation pump operates.
The factory default start time is 12:00AM (Midnight). The default duration
is 24 hours. To make adjustments, press the sensor labeled CYCLE five
times to enter the circulation pump programming mode. The LCD screen
will display ADJUST Circ. At this time the system is ready to accept your
changes.