Replacement Cylinder

The label on the existing cylinder identifies the cylinder type in its top left corner. When ordering
a cylinder always quote the three or five digit model number on the label, the humidifier's serial
number and the humidifiers voltage. Serial number and voltage are located on the specification
label on the left side of the humidifier.
Electrode Pin
Connect color coded cylinder
plugs to pin with corresponding
color label. There may be 2, 3
or 6 connections depending on
cylinder.
The spring loaded plug should
fit snugly on the pin. Replace if
loose or any signs of damage.
Label
Identifies cylinder type in
top left. Always replace
cylinder with the same
model.
Note: NORTEC recommends keeping several replacement cylinders in stock
throughout the humidification season. This will prevent possible downtime when the
humidifier reports cylinder end of life.
61 | Maintenance and Servicing
Steam Outlet
Secure steam hose to
outlet with hose clamp.
Electrode Internal
Mounting Point
Figure 42: NHTC/PC Cylinder
High Water Sensor Pin
Has a plastic collar
around it. Connect
orange high water
sensor wire here.