terminal (black) of the cable with the negative terminal
(black) of battery. Ensure the connection is secured by using
the fasteners provided. Refer to Fig. 4.8
Negative Terminal
(Black)
CAUTION
Do not reverse the polarity of the terminals when charging a
battery. Serious damage to the generator and/or battery may
occur.
NOTE:
The D.C. terminals on the battery must not be used while the A.C. outlet
is in use.
2.
Before starting the engine, do not connect the genera-
tor to the device
3.
Rotate the fuel valve to ON position. (Vertical position).
Refer to Fig. 4.9
Fig. 4.8
Postive Terminal
(Red)
27.