Heat & Glo Escape-42DV Owner's Manual page 28

Natural gas
Hide thumbs Also See for Escape-42DV:
Table of Contents

Advertisement

FRONT VIEW
REAR VIEW
G Y R
BLACK
WHITE
GROUND
TO HEAT
ZONE
BLACK
WHITE
GROUND
CONTINUOUS
110VAC
SUPPLY
Figure 10.1
Intellifire Pilot Ignition (IPI) Wiring Diagram
28
FIREBOX
OUTER
SURROUND
RED
YELLOW - HNG
WHITE - HTL
GREEN
Y
R
G
BLACK
FAN
CONNECTION
*
PLUG-ADP
GROUND
AC
PIGTAIL
PLUG
(GREEN)
HOT
NEUTRAL
Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05
MALE-MALE JUMPER WIRE
BROWN
BROWN
RED
BLACK
ORANGE
ORANGE
BLACK
AUX
CONNECTION
PLUG-ADP
RED
RED
Note: Appliance will not operate unless properly grounded.
* Must order PLUG-ADP separately if using the Heat-Zone.
GROUND BLACK
GREEN
ORANGE
1
IPI
2
3
MODULE
4
5
6
7
8
FLAME HIGH/LOW
FLAME ON
IPI
VALVE
FLAME
SOLENOID
FIREBOX
BACK
LIGHT 1
BACK
LIGHT 2

Hide quick links: