Gas Information; Fuel Conversions; Gas Pressures; Gas Connection - Heat & Glo Escape-42DV Owner's Manual

Natural gas
Hide thumbs Also See for Escape-42DV:
Table of Contents

Advertisement

9

Gas Information

A. Fuel Conversions
Before making gas connections ensure that appliance
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a quali-
fied technician using Hearth & Home Technologies speci-
fied and approved parts.
B.

Gas Pressures

Proper input pressures are required for optimum appliance
performance. Gas line sizing requirements need to be made
following NFPA51.
WARNING
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
• Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
WARNING
Verify inlet pressures.
• High pressure may cause overfire
condition.
• Low pressure may cause explosion.
Install regulator upstream of valve if
line pressure is greater than 1/2 psig.
Pressure requirements for appliance are shown in the table
below.
Pressure
Natural Gas
Minimum
5.0 inches
Inlet Pressure
Maximum Inlet
14.0 inches
Gas Pressure
Manifold
3.5 inches
Pressure
Propane
11.0 inches
w.c.
w.c.
14.0 inches
w.c.
w.c.
9.2 inches
w.c.
w.c.
Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05
C.

Gas Connection

NOTE: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI 223.1.
Installation should be done by a qualified installer approved
and/or licensed as required by the locality. (In the
Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.)
NOTE: A listed (and Commonwealth of Massachusetts ap-
proved) 1/2 inch (13mm) T-handle manual shut-off valve and
flexible gas connector are connected to the 1/2 inch (13mm)
control valve inlet.
• If substituting for these components, please consult
local codes for compliance.
Refer to Reference Section 16 for location of gas line ac-
cess in appliance.
WARNING
Gas Leak Risk
• Support control when attaching pipe to
prevent bending gas line.
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents