2. INSTALLATION

2.1 General instructions

This appliance must only be used for the purposes it has been specifically designed for. This appliance is
used to heat water to below boiling temperature at atmospheric pressure and must be connected
to a central heating and/or hot warm distribution system, according to its characteristics, perform-
ance and heating capacity. All other uses are considered improper.
THE BOILER MUST ONLY BE INSTALLED BY SPECIALIST AND QUALIFIED PERSONNEL, IN
COMPLETE COMPLIANCE WITH ALL THE INSTRUCTIONS REPORTED IN THIS TECHNICAL MANUAL,
THE LEGAL STANDARDS IN FORCE, THE PRESCRIPTIONS OF STANDARDS AND ANY LOCAL STAND-
ARDS, AND ACCORDING TO THE RULES OF GOOD PRACTICE.
Incorrect installation may cause injury or damager to persons and property. The manufacturer will not
be held liable in such events.
This appliance must be installed strictly in accordance with these instructions.
The Gas Safety Regulations (Installations & Use).
The Local Building Regulations.
The Building Regulations.
The Buildings Standards (Scotland - Consolidated) Regulations.
British gas publication DM2 - Guide for installation in timber framed housing.
British Standards Codes of Practice:
B.S.
7593
B.S.
5546
B.S.
5440
Part 1
B.S.
5440
Part 2
B.S.
5449
B.S.
6798
B.S.
6891
B.S.
7671
B.S.
4814
B.S.
5482
Model Water Bye Laws
For Northern Ireland the rules in force apply

2.2 Siting of appliance.

The appliance's combustion chamber is sealed from the surrounding environment and as a result the
appliance may be installed in any room without purpose built ventilation. The installation environment
must nonetheless feature sufficient ventilation, to avoid dangerous conditions arising in the event of
even minor gas leaks. These safety standards are imposed by EEC Directive no. 09/396 for all gas appli-
ances, including the so-called sealed appliances.
The place of installation must in any case be free of dust, inflammable objects or materials and corrosive
gases. The environment must be dry and not prone to freezing.
The boiler is supplied ready for wall-hung installation. The rear frame of the appliance has a series of
slots for fastening it to the wall, using screws with wall plugs. The fastening to the wall must provide
stable and effective support of the appliance.
The boiler must be fastened to a closed part of wall, which is free of apertures or holes behind the frame
of the boiler that may allow the internal components of the boiler to be reached.
If the appliance is enclosed in a cabinet or alongside another appliance, minimum clearances must be
adhered to. Fig. 2 and Tab. 3 show the minimum and recommended space to be left free around the
appliance.
6
TREATMENT OF WATER IN DOMESTIC HOT WATER CENTRAL HEATING SYSTEMS
INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES
FLUES
AIR SUPPLY
FORCED CIRCULATION HOT WATER SYSTEMS
INSTALLATION OF GAS FIRED HOT WATER BOILERS
GAS INSTALLATIONS
IEE WIRING REGULATIONS
SPECIFICATION FOR EXPANSION VESSELS
INSTALLATION OF LPG