Technical Data Table - Ferroli SYS 10-23 Installation, Maintenance And User Instruction

Wall-hung, gas-fired, system boiler, for central heating
Table of Contents

Advertisement

Sys 10 - 23

4.4 Technical data table

Output
Nominal Heat Input (Net)
Nominal Heat Output
Gas supply
Main injectors, Natural Gas (G20)
Supply pressure, Natural Gas (G20)
Burner pressure, Natural Gas (G20)
Natural gas rate (G20)
Main injectors, LPG (G31)
Supply pressure, LPG (G31)
Burner pressure, LPG (G31)
LPG gas rate (G31)
Central heating
Maximum central heating operating temperature
Maximum central heating operating pressure
Safety valve
Minimum central heating operating pressure
Expansion vessel capacity
Expansion vessel pre-fill pressure
Hot water capacity
Dimensions, weights, fittings
Height
Width
Depth
Weight with packaging
Gas system fittings (with isolation valve fitted)
C.H. flow (with isolation valve fitted)
Central heating return (with isolation valve fitted)
Power supply
Max Power Absorbed
Power supply voltage/frequency
Index of protection
Pmax
Pmin
kW
25,8
11,2
kW
23,3
Pmax
Pmin
mm
12 x 1.3
mbar
20,0
mbar
11,8
nm 3 /h
2,73
1,19
mm
12 x 0.77
mbar
36,0
mbar
36,0
kg/h
2,00
0,87
90
°C
bar
3
bar
3
bar
0,8
litres
8
bar
1
litres
1,5
mm
720
mm
400
mm
370
kg
35
mm
22
mm
22
mm
22
W
125
V/Hz
230/50
IP
X4D
9,7
2,5
7,0
31

Advertisement

Table of Contents
loading

Table of Contents