Coper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control (44 pages)
Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control (68 pages)
Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control installation, servicing and user instructions (48 pages)
Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control (48 pages)
Summary of Contents for Ferroli BLUEHELIX TECH S 45H
Page 1
BLUEHELIX TECH S 45H IT - ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE ES - INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO TR - KULLANMA, KURULUM VE BAK M TALIMATLAR EN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE FR - INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN RO - INSTRUC IUNI DE UTILIZARE, INSTALARE I ÎNTRETINERE...
In case of a fault (see cap. 4.4) the display shows the fault code (detail 11 - fig. 1) and, BLUEHELIX TECH S 45H is a high-efficiency, low emissions premix condensing heat during safety standby times, the messages "d3" and "d4".
Page 3
BLUEHELIX TECH S 45H Boiler electrically powered Heating temperature adjustment Switch on the power to the boiler. Use the heating buttons (details 3 and 4 - fig. 1) to adjust the temperature from a min. of 20°C to a max. of 80°C.
BLUEHELIX TECH S 45H If the room temperature is lower than the required value, it is advisable to set a higher Carry out the relevant connections according to the diagram in fig. 12 and the symbols order curve and vice versa. Proceed by increasing or decreasing in steps of one and given on the unit.
Page 5
BLUEHELIX TECH S 45H 3.4 Gas connection For coaxial connection, fit the unit with one of the following starting accessories. For the wall hole dimensions, refer to the figure on the cover. Any horizontal sections of the fume Before making the connection, ensure that the unit is arranged for operation exhaust must be kept sloping slightly towards the boiler, to prevent possible condensate with the type of fuel available.
IMPORTANT - THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION If the boiler is to be connected BLUEHELIX TECH S 45H to a collective flue or a single flue with natural draught, the flue or chimney must be expressly designed by profession- ally qualified technical personnel in conformity with the current regulations and be suita- ble for sealed chamber units equipped with fan.
Page 7
BLUEHELIX TECH S 45H Heating power adjustment To adjust the heating power, switch the boiler to TEST mode (see sec. 4.1). Press the heating buttons (details 3 and 4 - fig. 1) to increase or decrease the power (min. = 00 - max.
BLUEHELIX TECH S 45H Proceed in reverse order to refit the front panel. Make sure it is correctly hooked to the Fault Fault Possible cause Cure upper fastenings and is correctly positioned at the sides. When tightened, the head of code screw "A"...
Dichiarazione di conformità Il costruttore: FERROLI S.p.A. Indirizzo: Via Ritonda 78/a 37047 San Bonifacio VR dichiara che questo apparecchio è conforme alle seguenti direttive CEE: Direttiva Apparecchi a Gas 2009/142 • • Direttiva Direttiva Bassa Tensione 2006/95 • Direttiva Compatibilità Elettromagnetica 2004/108 •...
Page 13
FERROLI S.p.A. Via Ritonda 78/a 37047 San Bonifacio - Verona - ITALY www.ferroli.it...