Technical Data Table - Ferroli BLUEHELIX PRO RRT 32 C Instructions For Use, Installation And Maintenence

Table of Contents

Advertisement

4.4 Technical data table

Table. 9- Technical data table
Data
PRODUCT IDENTIFICATION CODES
COUNTRIES OF DESTINATION
GAS CATEGORY
Max. heating capacity
Min. heating capacity
Max. Heat Output in heating (80/60°C)
Min. Heat Output in heating (80/60°C)
Max. Heat Output in heating (50/30°C)
Min. Heat Output in heating (50/30°C)
Max. heating capacity in DHW
Min. heating capacity in DHW
Max. Heat Output in DHW
Min. Heat Output in DHW
Efficiency Pmax (80-60°C)
Efficiency Pmin (80-60°C)
Efficiency Pmax (50-30°C)
Efficiency Pmin (50-30°C)
Efficiency 30%
Gas supply pressure G20
Max. gas flow G20
Min. gas flow G20
CO
- G20
2
Gas supply pressure G31
Max. gas flow G31
Min. gas flow G31
CO
- G31
2
NOx emissions class
Max. working pressure in heating
Min. working pressure in heating
Heating adjustment max. temperature
Heating water content
Heating expansion vessel capacity
Heating expansion vessel precharge pressure
Max. working pressure in DHW
Min. working pressure in DHW
DHW flow rate t 25°C
DHW flow rate t 30°C
Protection rating
Power supply voltage
Electrical power input
Empty weight
Type of unit
PIN CE
44
BLUEHELIX PRO RRT 32 C
Unit
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
%
%
%
%
%
mbar
3
m
/h
3
m
/h
%
mbar
kg/h
kg/h
%
-
bar
bar
°C
liters
liters
bar
bar
bar
l/min
l/min
IP
V/Hz
W
kg
cod. 3541T030 - Rev. 00 - 10/2019
BLUEHELIX PRO RRT 32 C
0T3B3IGA
GB
II2H3+ (GB)
30.6
6.4
30.0
6.3
32.5
6.9
32.3
6.4
32.0
6.3
97.9
98.0
106.1
107.5
109.5
20
3.39
0.68
9 ±0.8
37
2.49
0.50
10 ±0.8
6
2.5
0.8
95
3.0
10
0.8
9
0.3
18.3
15.3
X5D
230V/50Hz
80
32
C13-C23-C33-C43-C53
C63-C83-B23-B33
Q
Q
P
P
NOx
PMS
tmax
PMW
D
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

0t3b3iga

Table of Contents