Remove The Gun From The Manifold; Install The Gun On The Manifold - Graco 244592 Instructions-Parts List Manual

Automatic electrostatic air-assisted spray gun a series
Hide thumbs Also See for 244592:
Table of Contents

Advertisement

Repair
Remove the Gun from the
Manifold
1. Remove the fluid supply hose from the fluid fitting
(22).
2. Loosen the bottom gun screw (31) until the gun sits
loosely in the mounting bracket slot (A). See F
22..
CAUTION
The piston return spring (105) is compressed
between the manifold and the gun body when they
are assembled. To avoid sudden movement of the
gun, loosen the bottom gun screw (31) before loosen-
ing the three manifold screws (106). This allows the
gun to move forward gradually as the manifold
screws are loosened. Hold the gun firmly in hand
while loosening the manifold screws.
3. Holding the gun firmly in hand, loosen the three
screws (106) from the back of the manifold.
4. Remove the gun from the manifold and take it to the
service area.
36
.
IG
Fig. 22. Remove Gun from Manifold
Install the Gun on the
Manifold
1. Make sure the gasket (112) and spring (105) are in
place on the manifold. See F
parts for damage and replace them as needed.
2. Secure the gun to the manifold by tightening the
three screws (106).
3. Secure the gun to the mounting bracket (102) by
tightening the bottom screw (31).
106
112
105
A
TI1721A
102
22
. 22.. Inspect the
IG
309298J

Advertisement

Table of Contents
loading

This manual is also suitable for:

309298jPro auto xs aaTi1713a

Table of Contents