Connect the Air and Fluid
Lines
F
. 3. shows a schematic of air and fluid line connec-
IG
tions, and F
. 5. shows the manifold connections. Con-
IG
nect the air and fluid lines as instructed.
WARNING
Electric Shock Hazard
To reduce the risk of electric shock or other
serious injury, the air supply hose must be
electrically connected to a true earth
ground. Use only Graco Grounded Air
Supply Hose.
1. Connect the Graco Grounded Turbine Air Supply
Hose (B) to the gun's turbine air inlet (TA) and con-
nect the hose ground wire (A) to a true earth ground
(N). The gun turbine air inlet fitting has a left-hand
thread to prevent connecting another type of air
hose to the turbine air inlet. See Accessories on
page 52 for further information about the hose.
2. Check the electrical grounding of the gun as
instructed on page 16.
3. Before connecting the fluid line (P1), blow it out with
air and flush it with solvent. Use solvent which is
compatible with the fluid to be sprayed.

Manifold Connections

A1
Not Used
A2
Atomization Air Inlet Fitting
Connect a 3/8 in. (10 mm) OD tube between this fitting and
the air supply.
CYL
Cylinder Air Inlet Fitting
Connect a 5/32 in. (4 mm) OD tube between this fitting and
the solenoid. For quicker response, use the shortest hose
length possible.
309298J
EXH
Shroud Exhaust Outlet Fitting
Connect a 1/4 in. (6 mm) OD x 4 ft (1.22 m) long tube to
this fitting.
FO
Fiber Optic Fitting (Optional)
Connect the Graco Fiber Optic cable (see page 14).
KV1
kV Switch 1 Air Inlet Fitting
Connect a 5/32 in. (4 mm) OD tube between this fitting and
the solenoid.
KV2
kV Switch 2 Air Inlet Fitting
Connect a 5/32 in. (4 mm) OD tube between this fitting and
the solenoid.
P1
Fluid Supply Inlet Fitting
Connect a 1/4 npsm swivel fitting between this fitting and
the fluid supply.
P2
Not Used
TA
Turbine Air Inlet Fitting
Connect the Graco Electrically Conductive Air Hose
between this fitting (left-hand thread) and the solenoid.
Connect the air hose ground wire to a true earth ground.
KV2
TA
CYL
P1
Fig. 5. Manifold Connections
Installation
KV1
FO
A2
EXH
TI1739A
13