Check For Fluid Leakage - Graco 244592 Instructions-Parts List Manual

Automatic electrostatic air-assisted spray gun a series
Hide thumbs Also See for 244592:
Table of Contents

Advertisement

Maintenance

Check for Fluid Leakage

WARNING
Fire and Explosion Hazard
If any fluid leakage from the gun is
detected, stop spraying immediately. Fluid
leakage into the gun shroud could cause
fire or explosion and result in serious injury
and property damage.
YY
ZZ
Fig. 18. Check for Fluid Leakage
28
Skin Injection Hazard
To reduce the risk of a fluid injection injury,
always follow the Pressure Relief Proce-
dure on page 18 when you stop spraying
and whenever you are instructed to relieve
the pressure.
During operation, periodically check the manifold
exhaust tube (YY) and both ends of the gun shroud (ZZ)
for the presence of fluid. See F
areas indicates leakage into the shroud, which could be
caused by leaks at the fluid tube connections or fluid
packing leakage.
If fluid is seen in these areas, stop spraying immediately.
Relieve the pressure, then remove the gun for repair.
YY
ZZ
TI1716A
WARNING
. 18.. Fluid in these
IG
TI1736A