3-20 Setting Up Your Server
IMPORTANT:
Power off the server and a peripheral device before connection.
Connecting a powered peripheral device to the powered server will
cause malfunctions and failures.
To connect a third-party peripheral device or interface cable to the
server, consult with your service representative for availability of
such a device or cable. Some third-party devices may not be used
for the server.
To connect a SCSI device, an optional SCSI controller must be
installed. The total length of a cable (including the connection cable
in SCSI device) must be 3 m or shorter.
Do not connect the serial ports with the telephone line directly.
If an additional LAN device is installed in PCI slot, it is hard to
push the catch of the connector with your finger that is connected to
the LAN port. Disconnect the connector pushing the catch with a
standard screwdriver. At this time, be very careful for the
screwdriver not to damage the LAN port or other ports.
Do not connect any devices to the connectors not instructed in this
subsection. Doing so could damage the device, your server, or both.
If you install the server on the rack and connect peripherals, bundle the cables by using cable tie or
the like so that they are not entangled.
IMPORTANT:
into contact with the rack door or the guide rails on the sides of the
server.
Form the cables in such a way that they will not come