Checking The Server Air Flow; Power Supply; Replacing The Power Supply - Supero SC835XTQ - R982B User Manual

Sc835x series
Table of Contents

Advertisement

Checking the Server Air Flow

Checking the Air Flow
1. Make sure there are no objects to obstruct airflow in and out of the server. If
necessary, route the cables through the cable rack.
2. Do not operate the chassis without drives or drive trays in the drive bays.
3. Use only recommended server parts.
4. Make sure no wires or foreign objects obstruct air flow through the chassis. Pull
all excess cabling out of the airflow path or use shorter cables.
5. Do not operate the server for extended periods of time without the air shroud
in the proper place.
5-7

Power Supply

The power supply is redundant and hot-swappable, meaning that the power supply
can be changed without powering down the system.

Replacing the Power Supply

Replacing the Power Supply
1. The server may continue running if only one power supply module is removed
at a time.
2. Unplug the power supply that will be replaced.
3. Push the release tab on the back of the power supply.
4. Pull the power supply out using the handle.
5. Replace the failed power module with another of the same model.
6. Push the new power supply module into the power bay until it clicks into the
locked position.
7. Plug the AC power cord back into the module and power up the server.