Download Print this page

Rangemaster BELHD80 Instruction Manual

Bellini hood

Advertisement

Quick Links

BELHD80 - BELLINI HOOD
Instructions Manual
www.rangemaster.co.uk

Advertisement

loading

Summary of Contents for Rangemaster BELHD80

  • Page 1 BELHD80 - BELLINI HOOD Instructions Manual www.rangemaster.co.uk...
  • Page 2: Table Of Contents

    INDEX RECOMMENDATIONS AND SUGGESTIONS ........................3 CHARACTERISTICS ................................4 INSTALLATION..................................6 USE ......................................9 MAINTENANCE ................................... 11...
  • Page 3: Recommendations And Suggestions

    RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
  • Page 4: Characteristics

    CHARACTERISTICS Components Ref. Q.ty Product Components Hood Body, complete with: Controls, Light, Blower, Filters Upper Section Lower Section Directional Air Outlet grille Flange Angle iron Filter cover Ref. Q.ty Installation Components 7.2.1 Upper Chimney Section Fixing Brackets Wall Plugs Wall Plugs SB 12/10 Screws 4,2 x 44,4 Screws 2,9 x 6,5 Screws 2,9 x 9,5...
  • Page 5 Dimensions R100...
  • Page 6: Installation

    INSTALLATION Wall drilling and bracket fixing As a first step, proceed with the following drawings: • a vertical line up to the ceiling or up to the upper limit, at the centre of the area in which the hood is to be fitted; •...
  • Page 7 Fitting the hood body • Open the doors/the door (See section Open Panels). • Remove the Metal grease filters using the handles provided. • Adjust the two screws Vr, in the brackets 11a, so that they are at the start of their travel. •...
  • Page 8 ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is cor- rectly inserted in the socket placed on the side of the fan.
  • Page 9: Use

    Control panel Button Function Motor off. The Leds indicating the Speed of the motor turn off. Enables / Disables Keyboard Lock mode if pressed All the Leds light up in cycle and run a start-up sequence. and held for 5 seconds. Activates speed one.
  • Page 10 REMOTE CONTROL (OPTIONAL) The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03- AAA type (not included). • Do not place the remote control near to heat sources. • Used batteries must be disposed of in the proper manner. Opening Panel •...
  • Page 11: Maintenance

    MAINTENANCE Metal grease filters These can also be washed in the dishwasher, and need to be cleaned whenever the 24H Led comes on or at least once every 2 months use, or more frequently if use is particularly intensive. Resetting the alarm signal •...
  • Page 12 Activated Charcoal Filter (Recirculation Version) The Activated Charcoal Filter is only present on the Hoods in Recirculation version, and has the job of retaining smells in the flow of air that passes over it, until reaching saturation. This cannot be washed or regenerated, and must be changed when the Delay led on the display starts to flash, or at least once every 4 months.
  • Page 16 AGA RANGEMASTER GROUP PLC 991.0301.526_ver3...