Unpack the Unit / Warranty
1
Install Barrel Holder
2
Note: If you prefer, the wire adapter hose
holder can be mounted on the opposite side of
the cabinet, separately from the barrel holder.
Connect Air Input
Note: Clean, dry filtered factory air is required to meet
3
warranty. If your air supply is not filtered, order the EFD
five micron filter regulator (EFD part #2000F755).
Turn air pressure regulator knob to zero before connecting
main air input to the Ultra 1400.
• Push one end of the 6 mm air input hose into the input fitting
• Connect the other end of the hose to your plant air supply.
• Set plant air supply at minimum 80 to 100 psi (5.5 to 6.9 bar).
Unpack the unit.
Now is a good time to activate your Two Year Warranty. Register the
warranty online at www.efd-inc.com/warranty/two. Or if you prefer, follow
the instructions in the enclosed "Welcome" letter to contact your EFD
representative.
Remove sleeve from barrel holder.
Insert 6 mm screw through wire adapter
hose holder, then through barrel holder
Tighten screw to secure holder to
dispenser cover. Holder can be mounted
left or right.
Insert barrel holder sleeve.
on the back of the Ultra 1400.
A standard 1/4-inch NPT fitting is included with your dispenser.
.
Getting
Started
air input
7