Timed Mode
Start by setting the dispense time to zero. Press the
Press the Time Set buttons below the panel to set a specific dispense time. Be sure the decimal
is in the correct position for the time required.
In Timed mode, the Ultra 1400 will dispense a single deposit each time you press the foot
pedal. The deposit size is based on the dispense time and air pressure settings.
Abort Dispense
Press the foot pedal once to dispense. Press it a second time in mid-deposit to abort the
dispense cycle and reset to the original time display.
Air Pressure
Pull out the air pressure regulator knob to unlock it (bottom left knob).
Turn the knob clockwise to the desired pressure setting.
To reduce the pressure, turn the knob counter-clockwise until
pressure is lower than needed. Then increase the pressure until
you reach the correct setting.
Push the knob in to lock the pressure setting.
Vacuum
During initial testing and setup we recommend that you keep the vacuum
control shut off (turned completely clockwise; do not force).
Vacuum is required when dispensing thin fluids.
Turn the knob counter-clockwise to the desired vacuum setting.
See page 14 for details on using the Vacuum control.
Air Output Port
Push in the black quick-connect from the EFD adapter assembly to the air
output port, located on the front of the Ultra 1400. Twist to lock. Note: air
does not flow through the port until a quick-connect is installed.
button twice to zero the display.
air pressure regulator
Features &
Controls:
Front Panel
vacuum regulator
air output