2. Mounting the Equipment
Pro Logic Control Center
The Pro Logic is contained in a raintight enclosure that is suitable for outdoor mounting. The control must be mounted
a minimum of 5 ft. (2 meters) horizontal distance from the pool/spa (or more, if local codes require). The Control
Center is designed to mount vertically on a flat surface with the knockouts facing downward. Because the enclosure
also acts as a heat sink (disperses heat from inside the box), it is important not to block the four sides of the control. Do
not mount the Pro Logic inside a panel or tightly enclosed area.
When selecting a location, note that the standard cables supplied with the Turbo Cell, flow switch, temperature sen-
sors, and valve actuators (if applicable) are all 15 ft. (5m) long.
Temperature Sensors
Three sensors are included with the Pro Logic. A water sensor and an air sensor must be installed at all times for
proper operation. A solar sensor is required if the solar function is enabled.
Water Sensor
This sensor is used to measure the pool/spa temperature and is installed in the filtration plumbing after the filter but
before either the solar or conventionally fueled heaters—refer to the plumbing overview diagram.
1. Drill a 3/8" (10mm) diameter hole in the PVC piping and remove all chips and burrs.
2. Insert sensor until O-ring collar sits flush on the hole.
3. Position hose clamp over the sensor and gently tighten until O-ring makes an adequate seal. Do not overtighten.
4. For maximum temperature accuracy, cover the sensor and 3" (6cm) of pipe on either side with insulation and
white paint.
Air Sensor
Mount the air sensor outdoors.
!
IMPORTANT: Mount the air sensor out of direct sunlight.
Solar Sensor
For solar applications, mount the sensor near the solar collector array so that it is exposed to the same sunlight as the
collectors. Use additional cable (20 AWG) if necessary.
Optional Chlorination Function
The PL-P-4 model requires the use of a chlorinator cell and plumbing kit to provide pool chlorination. These items are
not included with the Pro Logic and can be purchased separately at your local Goldline dealer. Choose a chlorinator
cell model based on the size of your pool. The following models are available:
T-CELL-15 for pools up to 40,000 gallons
T-CELL-9 for pools up to 25,000 gallons
T-CELL-3 for pools up to 15,000 gallons
In addition to the chlorinator cell, a plumbing kit (P-KIT) must be purchased. This kit contains the cell unions and flow
switch. Refer to pages 8 and 17 for plumbing and wiring instructions.
Optional AQL-CHEM ORP and pH Sensing Kit
The AQL-CHEM is an ORP and pH sensing kit for the Pro Logic. When chlorination is enabled (requires chlorinator
cell and P-KIT), the Pro Logic senses the pool's ORP and pH levels and generates the correct amount of chlorine to
keep your pool properly sanitized. Wiring and plumbing requirements for the AQL-CHEM should be considered
before installing the Pro Logic. Refer to the AQL-CHEM manual for specific installation information.