Goldline Pro LOGIC PL-P-4 Installation Manual page 20

Automation and chlorination
Table of Contents

Advertisement

VSC Pump Address Setting
For proper communications, a pump address must be set for each VSC used in the system. For single pump systems,
the VSC address should be set to 001. When using Dual Equipment, the Pool Filter pump should be set to 001 and
the Spa Filter pump should be set to 002. Refer to the TriStar Pump Owner's Manual (IS3220VSC) and Hayward
document IS3220VSCAQLL for specific instructions on setting the pump address.
Temperature Sensors
The Pro Logic utilizes 10K ohm thermistor type sensors. Three sensors (water temperature, air temperature and solar
temperature) are included. If the Pro Logic is being used to control a solar heating system, the solar sensor is required.
The sensors are provided with a 15 ft. cable. See page 5 and the diagram below for installation information.
POOL/SPA
SENSOR
AIR
SENSOR
SOLAR/SPA
SENSOR
Remote Display/Keypad
The Pro Logic main unit can connect to a maximum of 3 remote wired display/keypads (ordered separately).
Use four conductor cable (typically phone cable) to connect the wired remote display/keypad with the Pro Logic
Control Center as shown below. The maximum wiring distance is 500ft. (160m). Note that the terminals on both the
Pro Logic main unit and the wired remote display/keypad are numbered: Connect 1 to 1, 2 to 2, etc. Refer to diagram
below.
3.75 "
Remote Display unit
4.50 "
4
3
2
1
Alternative
Concealed Wiring
500 ft max
If multiple remote display/keypads are installed: Never connect more than 2 wires to any terminal block. Two
remotes can be wired back to the Pro Logic main unit or the second display/keypad (and third, if applicable) can be
"daisy chained" with one display/keypad wired to the next. The maximum wire run from the Pro Logic main unit to the
furthest remote display/keypad is 500 ft (160m).
17

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Goldline Pro LOGIC PL-P-4

Table of Contents