After plumbing and wiring are complete, the Pro Logic MUST BE CONFIGURED before attempting to operate.
Configuration information is entered at the keypad and "tells" the Pro Logic what equipment is connected and how
each should be controlled.
Accessing the Configuration Menus
Configuring the Pro Logic requires that you navigate through the Configuration Menu and input various informa-
tion. For more detailed information about using the Pro Logic menu system, refer to the Operation Manual.
To access the Configuration Menu
Configuration
Menu-Locked
Configuration
Menu-Unlocked
NOTE: The configuration menu automatically "locks" after 2 minutes of no buttons being pressed to
prevent unauthorized people from changing the control logic inadvertently and possibly damaging
the pool equipment or causing a "call back" to fix the configuration.

Configuration Menu Items

Each item needs to be programmed and may contain additional sub-menu items. Refer to the following pages for
information on programming.
Chlor. Config.
Chlor. Config.
+ to view/change
+ to view/change
Chlorinator
Chlorinator
Enabled
Enabled
Display
Display
Salt
Salt
Cell Type
Cell Type
T-CELL-15
T-CELL-15
Requires the use of a chlorinator cell and P-KIT sold separately. If the chlorinator is enabled, then
the cell and flow switch must also be installed and the Pro Logic will automatically chlorinate both the
pool and spa according to the desired output setting (see Settings Menu in the Operation manual). If
disabled (default), all displays relating to the chlorinator will be suppressed.
When the chlorinator is enabled, the Pro Logic will automatically detect and control any Aqua Rite(s)
that is installed in the system.
Display
Allows for the display of salt (default) or mineral values.
Cell Type Selection
The Cell Type Menu appears after "Display Salt/Minerals" in the Chlorinator Configuration Menu.
The options are T-CELL-15 (default), T-CELL-9, T-CELL5 or T-CELL-3. Make the proper selection
based on the chlorinator cell that is used in your system. Refer to the information below.
"T-CELL-3" = T-CELL-3, GLX-CELL-3-W
"T-CELL-5" = GLX-CELL-5, GLX-CELL-5-W
"T-CELL-9" = T-CELL-9, GLX-CELL-9-W
"T-CELL-15" = T-CELL-15, GLX-CELL-15-W
5. Configuration Menu
Press repeatedly until "Configuration Menu" is displayed
Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock
Move to configuration menu items
Push to access Chlorinator option
Move to next configuration menu
Toggle between Chlorinator Enabled and Disabled (default)
Move to next menu item
Toggle between Display Salt (default) and Minerals
Move to previous/next configuration menu
Rotates between available Cell types
Move to next menu item
Chlorinator