Goldline Pro LOGIC PL-P-4 Installation Manual page 26

Automation and chlorination
Table of Contents

Advertisement

Freeze Protection Speed
This menu only appears if freeze protection is enabled and the pump is configured for 2-speed or variable
speed pump operation. This is the speed that the pump will run at during freeze protection operation.
Select high (default) or low speed operation.
Freeze Protection Temperature
Select the temperature to be used for freeze protection. Temperature is adjustable from 33ºF - 42ºF (1ºC -
6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have freeze protection enabled.
External Input Interlock
When enabled, the filter pump will be forced off when the external input is active. Note that freeze
protection will have precedence over this feature.
Heater1 Config.
+ to view/change
Heater1
Disable
if "Heater1" is enabled
Heater1 Cooldown
Disabled
if "Heater1" is enabled
Heater1 Extend
Disabled
if "Heater1" is enabled and
1-speed filter pump is not selected
Allow Low Speed
Disabled
Heater1
If the heater is "Enabled", the heater relay will turn on when the water temperature is less than the desired
temperature setting and the filter pump is running. The desired temperature is in the "Settings Menu". If
applicable, the homeowner will be prompted to enter separate "pool" and "spa" settings. Depending on
the position of the pool/spa suction valve, the proper temperature setting will be used.
Heater Cooldown
This feature ensures that the heater cools down before water circulation is stopped. When enabled, the
Pro Logic will continue to run the filter pump for 5 minutes after the heater turns off. During this period the
filter pump LED will flash and also a "Heater Cooldown, X:XX remaining" message will scroll on the
display.
When the filter pump is running and the heater is on: Pressing the "Filter" button once will cause the
heater to turn off, but the filter pump will continue to run for heater cooldown (filter LED flashing and
message on display). Pushing the filter button a second time will override the heater cooldown operation
and turn the filter pump off.
Heater Extend
If "Enabled", the filter extend logic keeps the filter pump running beyond the normal turn-off time until the
pool (or spa) is heated up to the desired temperature setting (see Settings Menu). Heater extend will NOT
cause the filter pump to turn on, it will only delay the turn off time when the heater is operating.
Allow Low Speed
This menu only appears if the filter is configured for 2-speed or variable speed operation. During default
operation, high speed mode is used whenever the heater is on. If Allow Low Speed is enabled, low speed
will be allowed even if the heater is on.
Push to access heater options
Move to previous/next configuration menu
Toggle between Enabled and Disabled (default) Heater 1
Move to next menu item or previous/next configuration menu
Toggle between Enabled and Disabled (default) Heater 1 Cooldown
Move to next menu item
Toggle between Enabled and Disabled (default) Heater 1 Extend
Move to previous/next configuration menu
Toggle between Enabled and Disabled (default)
Move to next menu item or previous/next configuration menu
23