Goldline Pro LOGIC PL-P-4 Installation Manual page 30

Automation and chlorination
Table of Contents

Advertisement

Super Chlorinate – if "Chlorinator" is enabled, this option allows the user to start a Super Chlorinate cycle
when the Aux button is pressed, rather than using the Settings Menu. Note that only one button can be
assigned to this function.
Aux1 Relay
This feature allows the user to select either "Standard" (default) or "Dimmer" type relay for the Aux1
output. The optional AQL-DIM dimmer kit must be installed if "Dimmer" is desired. When "Dimmer" is
selected, and the Aux1 output is manually turned on, the "+" and "-" buttons adjust the level from 20% to
100% (default). The level is saved for the next time the aux1 output is turned from off to on.
Aux1 Interlock
If "Enabled", this feature will override the function (Manual On/Off, Countdown Timer, Timeclock), selected
above and turn the aux1 off when: filter pump is off, first 3 minutes of filter pump operation (allows the
pump to prime and get water flowing), when the pool/spa suction return valves are in any position other
than "pool only", or for the first 3 minutes after solar turns on (allows air in the solar panels to be purged).
Interlock is not available for solar, low speed filter pump, super chlorinate or dimmer.
Aux1 External Input Interlock
When enabled, Aux1 will be forced off when the external input is active. Note that freeze protection does
NOT have precedence over this feature.
Aux1 Freeze Protection
This function protects the pool, plumbing, and equipment against freeze damage. If Freeze Protection is
enabled and the AIR temperature sensor falls below the selected freeze temperature threshold, the Pro
Logic will turn on the aux relay to circulate the water. IMPORTANT: this only enables operation of the
AUX output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main
circulation system.
Valve3 Config.
+ to view/change
Valve3 Function
Solar
for all functions except solar and super chlorinate
Valve3
Interlock
Disabled
for all functions except solar or super chlorinate
Valve3 Ext Input
Disabled
for all functions except super chlorinate
Valve3
Freeze
Disabled
Valve3 Function
Timeclock (default) – the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu
(see Operations Manual). The VALVE3 button can also be used to turn the valve output on or off.
Solar – the valve operates when the filter pump is running and solar heat is available and the water is less
than the desired temperature setting. Solar heating must be enabled in the "Solar Config. menu for proper
operation to occur.
In-Floor Cleaner – the valve switches the water returning to the pool between the in-floor cleaner and the
normal return jets which facilitate efficient surface skimming. The valve will operate the in-floor cleaner for
the first half of each clock hour and then switch to the jets/skimming for the last half of the hour.
Super Chlorinate – if "Chlorinator" is enabled, this option allows the user to start a Super Chlorinate cycle
when the Valve3 button is pressed, rather than using the Settings Menu. Note that only one button can be
assigned to this function.
Push to access Valve3 options
Move to previous/next configuration menu
Rotates between
Timecloc (default), Solar, In-floor Cleaner,
and Super Chlorinate
Move to next menu item
Toggle between Enabled and Disabled (default) Valve3 Interlock
Move to next menu item
Toggle between Enabled and Disabled (default)
Move to previous/next configuration menu
Toggle between Enabled and Disabled (default) Valve3 Freeze
Move to previous/next configuration menu
k