Goldline Pro LOGIC PL-P-4 Installation Manual page 27

Automation and chlorination
Table of Contents

Advertisement

Solar Config.
+ to view/change
Solar
Disabled
if "Solar" is enabled
Solar-Extend
Disabled
if "Solar" is enabled
Solar Priority
Disabled
if "Solar" is enabled and
"1-speed Filter" is not selected
Allow Low Speed
Disabled
Solar
If the solar control logic is "Enabled", several additional steps must be taken to ensure
proper operation of the solar system. If the solar is operated by a valve, then the Valve3
output must be setup for solar logic (page 27). If the solar is operated by a pump, then one
of the AUX relays must be set up for solar logic (page 26). Also, the "solar" temperature
sensor must be installed. This sensor is typically mounted near the collector array and is
used to sense whether sufficient solar heat is available.
If solar is "Enabled", the valve or solar pump relay will turn on when the water temperature is
less than the desired temperature setting AND the solar sensor is hotter than the water. The
desired temperature is in the "Settings Menu". If applicable, the homeowner will be prompted
to enter separate pool and spa desired temperature settings. Depending on the position of
the pool/spa suction valve, the proper temperature setting will be used.
Solar Extend
If "Enabled", the filter extend logic keeps the filter pump running beyond the normal turn-off
time if solar heat is still available. When solar heat is no longer available, both the solar
valve/pump and filter pump will turn off simultaneously. Solar extend will NOT cause the
filter pump to turn on, it will only delay the turn off time when solar is operating.
Solar Priority
If both "Solar Control" and "Heater Control" are enabled, the Solar Priority feature will keep
the conventional heater off whenever solar heat is available. This provides the most cost
effective way of heating the pool. When solar heat is not available, the conventional heater
will operate normally.
Allow Low Speed
This menu only appears if the pool filter is configured for 2-speed or variable speed operation.
During default operation, high speed mode is used whenever the solar heater is on. If Allow
Low Speed is enabled, low speed pump operation will be allowed during solar heating except
for the first 3 minutes after solar heat turns on.
External Input
Active Closed
External Input
The external input device can either be normally open or normally closed. In this menu,
select the state of the external input device when active.
Push to access solar options
Move to previous/next configuration menu
Toggle between Enabled and Disabled (default) Solar
Move to next menu item or previous/next configuration menu
Toggle between Enabled and Disabled (default) Solar Extend
Move to next menu item
Toggle between Enabled and Disabled (default) Solar Priority
Move to next menu item
Toggle between Enabled and Disabled (default)
Move to next menu item or previous/next configuration menu
Toggle between Open and Closed (default)
Move to next menu item or previous/next configuration menu
24