External Input Interlock
The External Input Interlock provides a means to force the filter pump or an Aux output off when certain conditions
exists. A normally open or normally closed on/off external device must be connected to the Pro Logic as shown below.
After properly configuring the Pro Logic (see Configuration), the filter pump and/or desired Aux will be forced off
when the device is active.
(either Normally Open or Normally Closed)
Goldline Aqua Rite Chlorinator
The Pro Logic can control one or more Goldline Aqua Rite chlorinators when additional sanitizing capacity is required.
A 4 wire connection is used to communicate to the Aqua Rite and can be wired up to 500' apart. Any outdoor rated
4 conductor cable can be used. Refer to the wiring diagrams below for proper wiring connection to the Aqua Rite.
NOTE: There must be only 1 "primary" unit. All other Aqua Rite units must be configured as "secondary".
Pro Logic
Pro Logic
SPST External Switch
Jumper Installed
For Primary
(Factory Default)
Aqua Rite
(Primary)
NOTE: Primary/Secondary jumper is located underneath small circuit board.
GRN
4
YEL
3
BLK
2
1
RED
GREEN
4
YELLOW
3
BLACK
2
Jumper Removed
RED
1
For Secondary(s)
Aqua Rite
(Secondary)
green
GRN
4
yellow
YEL
3
black
BLK
2
red
RED
1
19
Additional
Aqua Rite(s)
(if required)
Aqua Rite

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Goldline Pro LOGIC PL-P-4

Table of Contents