AirLive SNMP-FSH2602MG User Manual

AirLive SNMP-FSH2602MG User Manual

26+2-port snmp/web management switch
Table of Contents

Advertisement

Quick Links

SNMP-FSH2602MG
26+2-port SNMP/Web
Management Switch
User's Manual
AirLive SNMP-FSH2602MG User's Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SNMP-FSH2602MG and is the answer not in the manual?

Questions and answers

Summary of Contents for AirLive SNMP-FSH2602MG

  • Page 1 SNMP-FSH2602MG 26+2-port SNMP/Web Management Switch User’s Manual AirLive SNMP-FSH2602MG User’s Manual...
  • Page 2: Declaration Of Conformity

    OvisLink Corp. 5F., NO.6, Lane 130, Min-Chuan Rd., Hsin-Tien City, Taipei County, Taiwan Declare that the product 26+2-port SNMP/Web Management Switch SNMP-FSH2602MG is in conformity with In accordance with 89/336 EEC-EMC Directive and 1999/5 EC-R & TTE Directive Clause Description...
  • Page 3 Directiva disposiciones aplicables o exigibles de la 1999/5/CE. Directiva 1999/5/CE. ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ OvisLink Corp. ΔΗΛΩΝΕΙ OvisLink Corp izjavlja, da je ta SNMP-FSH2602MG v Ελληνική [Greek] ΟΤΙ SNMP-FSH2602MG ΣΥΜΜΟΡΦΩΝΕΤΑΙ Slovensko skladu z bistvenimi zahtevami in ostalimi relevantnimi ΠΡΟΣ...
  • Page 4: Fcc Warning

    Trademarks All rights reserved. AirLive Logo is a registered trademarks of OvisLink Corp., Taiwan. Other product names and company names are trademarks or registered trademarks of their respective owners. FCC Warning This equipment has been tested and found to comply with the requirements for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 5: Table Of Contents

    Desktop Installation ......................9 Cabling Requirements ...................... 9 For 100BASE-TX and 1000Base-T ports ............... 9 Auto MDI/MDI-X function ..................10 Making your own UTP/STP cable ................10 Connecting to Power ....................... 11 3 LED INDICATORS ..................12 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 6 Port Statistics ........................20 Show MAC Table ......................23 Administrator ........................24 IP and Management Mode (Administrator menu) ............24 Switch Setting (Administrator menu) ................25 Advanced settings ......................25   MAC Address Age-out Time ................26 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 7 Setting Spanning Tree ....................43 Port Mirror (Administrator menu) ................44 SNMP/Trap Manager (Administrator menu) .............. 45 Security Manager (Administrator menu) ..............46 Introduction to 802.1x Authentication Protocol ............47 802.1x Configuration (Administrator menu) ............... 48 System Configuration ....................48 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 8 Trunk Configuration ...................... 65 VLAN Configuration ...................... 66 VLAN Configure ......................66 Create a VLAN Group ....................67 Create 802.1Q VLAN ....................68 Edit / Delete a VLAN Group ..................69 Groups Sorted Mode ..................... 70 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 9 Port Counters ......................105 System Information ..................... 105 Reboot Switch ........................ 106 Default ......................... 106 Restart ......................... 106 TFTP Update Firmware ....................107 TFTP Update Firmware ....................107 Restore Configure File ....................108 Backup Configure File ....................109 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 10 Figure 4-16 Enable VLAN configuration ..............37 Figre 4-17 Configure Port-Based VLAN ..............39 Figure 4-18 Configure 802.1Q/V VLAN ..............40 Figure 4-19 Set Spanning Tree ..................43 Figure 4-20 Span Tree Port Parameter ................. 44 Figre 4-21 Port Mirror ....................45 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 11 Figure 5-2 Remote Management through direct Internet ..........56 Figure 5-3 Remote Management through Broadband Router ........57 Fig. 5-4 RS-232 Cable ....................58 Fig. 5-5 Console Port ....................59 Fig. 6-3 RS-232 Cable ....................59 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 12 Table 2-1 Module Specification Table ................7 Table 2-2 Cabling type for 10/100BASE-TX and 1000Base-T ........10 Table 3-1 LED Table ....................13 Table 4-1 IGMP Snooping Messages ................35 Table 4-2 Span Tree Setting Parameters ..............44 AirLive SNMP-FSH2602MG User’s Manual viii...
  • Page 13: Product Overview

    At any time, users can click on the “help” icon for setup instruction inside the web management. This user’s manual will help you to uncover most functions of the SNMP-FSH2602MG with step-by-step instructions presented by high quality illustrations. Thank you for choosing OvisLink’s product.
  • Page 14: Quick Setup

    Power-On the switch The SNMP-FSH2602MG has a built-in power supply to operate with 90 ~ 260V AC, 50 ~ 60Hz power source. The AC power cord connector is located at the rear of the unit and the On/Off switch is next to the connector.
  • Page 15: Console Port Information

    Station Port LEDs ● Green Connection Established Link/Act Blinking Transmitting/Receiving No connection is made ● Green 100 Mbps Connection 100M 10 Mbps Connection Gigabit port LED ● Green 1000Mbps Connection Top LED ● Green Blinking Transmitting/Receiving Bottom LED AirLive SNMP-FSH2602MG User’s Manual...
  • Page 16: Installation Of The Switch

    Chapter 4 for further instruction. Telnet Management: for instruction on management using Telnet, please see Chapter 5 for further instruction. Console Port Management: for instruction on management through console port, please see Chapter 5 for further instruction. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 17: Unpack The Package

    Unpack the Package Before you begin the installation of SNMP-FSH2602MG, make sure that you have all the necessary accessories that come with your package. Follow the steps below to unpack your package contents: 1. Clear out an adequate space to unpack the package carton.
  • Page 18: Hardware Overview

    The Rear & Side Panel The rear panel and side panel is where you can locate the power switch, AC power connector, and cooling fans. Cooling FAN Power Switch Power Connector Fig. 2-3 Rear & Side Panel AirLive SNMP-FSH2602MG User’s Manual...
  • Page 19: Module Installation

    Mini-GBIC modules. Installation Site Preparation You can mount SNMP-FSH2602MG either on desktop or on a 19-inch rack. If you plan to mount the switch on desktop, please choose a steady, level surface in a well-ventilated area that is free from excessive dust.
  • Page 20: Rack Mounting

    Leave at least 10cm(4 inch) of space around the switch to allow heating dissipation Rack Mounting SNMP-FSH2602MG can be mounted on a standard size 19-inch rack, which can in turn be placed in a wiring closet with other equipments. Before you can mount the switch on the rack, first you must attach the mounting brackets on both sides of the switch with screws, and then mount it as a unit on the rack.
  • Page 21: Desktop Installation

    Fig. 2-5 attaching the Switch to a 19-inch rack Desktop Installation SNMP-FSH2602MG has four rubber pads attached on each corner of its underside. These pads serve as cushioning against vibration and prevent the switch from sliding off its position. They also allow adequate ventilation space when you place the switch on top of another device.
  • Page 22: Auto Mdi/Mdi-X Function

    (CAT 5E recommended) Auto MDI/MDI-X function The SNMP-FSH2602MG is equipped with Auto-MDI/MDI-X function, which allows you to use straight-thru cable even when connecting to another switch/hub. Simply use the straight-through cable for all types of 10/100/1000BASE-TX connections, either to a PC or to a networking device such as other hub or switch.
  • Page 23: Connecting To Power

    Connecting to Power SNMP-FSH2602MG features a universal auto-select power supply unit, which allows a power connection to a wide range of input voltages from 90 to 260V @ 50 ~ 60Hz. To establish its power connection, simply plug the female end of the power cord into the power connector on the rear of the switch and the male end of the power cord into a suitable power outlet.
  • Page 24: Led Indicators

    LED Indicators Before connecting any network device to SNMP-FSH2602MG, you should take a few minutes to look over this chapter and get familiar with the front panel LED indicators of your Switch. Comprehensive LEDs The front-panel LED indicators of SNMP-FSH2602MG comprise 3 sets of LEDs: System Status LEDs, Station Port LEDs, and Gigabit port LEDs.
  • Page 25: Station Port Leds For Port 1 ~ 24

    Station Port LEDs for Port 1 ~ 24 The SNMP-FSH2602MG is equipped with 2 LEDs on the sides of each RJ-45 station port. This design allows users to view the status of each port quickly. The left LED indicates the Link/Action Status.
  • Page 26: Web Management

    Web Management The SNMP-FSH2602MG supports in-band management through web browser. In this session, you will learn how to access the switch’s powerful management functions through the web browser. You will also learn how to manage the switch remotely through Internet.
  • Page 27: Configure Your Computer's Ip

    “Start -> Settings -> Network -> Local Connection” of the task bar’s Start menu. Step 2: Click on the “property” icon. Step 3: Double click on the “Internet Protocol (TCP/IP) Step 4: AirLive SNMP-FSH2602MG User’s Manual...
  • Page 28: Remote Management

    *Note2: If IP address of the switch is lost, please use console port management to find the switch’s IP address. *Note3: The SNMP-FSH2602MG has DHCP client ability. This allows DHCP server (or router) to assign IP automatically. However, we do not recommend turning on the DHCP client because the DHCP server assign the IP randomly.
  • Page 29: Connect Through Broadband Router

    Web browser’s address field. Get into the Web Management After you have properly configured the computer and switch’s IP, you can get into the web management by the following steps: Step 1: Open the Internet Explorer AirLive SNMP-FSH2602MG User’s Manual...
  • Page 30: Menu Bar

    2-port 1000Base-TX module even when there is no module installed. However, clicking on the module port state will show whether the port is installed. If only 1-port module is installed, Port-25 will show the status of the single module port. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 31: Port Status

    Ingr: Display the port effective ingress rate of user setting. Egr: Display the port effective egress rate of user setting. Port Security: Display the port security is enabled or disabled. Config: Display the state of user setting. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 32: Single Port Status

    There are three pages the switch provides for user to monitor the statistics of network traffic: Port Summary, RMON Statistics(1), RMON Statistics(1) Graph, RMON Statistics(2). Click on the Port Statistic will bring up the traffic statistics on Port Summary for all ports; click on the reset will refresh the counter. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 33: Figure 4-5 Port Stastics

    256-511, 512-1023, and 1024-1518 bytes, the total received packets and the total receives bytes. The second part collects the information about drop events, broadcast packets, multicast packets, alignment errors, undersize packets, oversize packets, fragments, jabbers and collisions. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 34 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 35: Show Mac Table

    A sorting function is implemented here. Clicking header on the top of table will bring a new sorted list of current content in the order of its title. For instance, clicking the “MAC” on the top of table will refresh the table by the index of “MAC”. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 36: Administrator

    ”Agent IP “setting and “Agent management” in the main menu will not show up if the agent mode is set as “Slave”. [Note] If any of the value is changed in this field, reboot is necessary. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 37: Switch Setting (Administrator Menu)

    The switch setting menu under the Administrator’s menu is where you can configure auto-aging time, Broadcast Storm Control, 802.1p Priority, and to enable the 802.1x protocol. It also provides basic information about the switch and module. Advanced settings Figure 4-9 Advance Switch Settings AirLive SNMP-FSH2602MG User’s Manual...
  • Page 38: Mac Address Age-Out Time

    “The Priority Queue Service settings” is where you can configure the 802.1p Priority and QoS settings. This is also the place where users can enable or disable the 802.1x authentication protocol. You can find this setting in the Administrator->Switch Settings ->Advanced menu. Figure 4-10 802.1p Priority Settings AirLive SNMP-FSH2602MG User’s Manual...
  • Page 39: 802.1P Priority

    Disable – In half duplex, collision-retry maximum is 48 times and packet will be dropped if collision still happen. Enable – In half duplex, if happen collision will retry forever. 802.1x Protocol Enable or disable 802.1x protocol. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 40: Console Port Information (Administrator Menu)

    Port Controls (Administrator menu) User may modify or change mode operation in this page. Please select a port under the “Port” field and modify the port configuration in the subsequent field. Figure 4-11 Port Control Settings AirLive SNMP-FSH2602MG User’s Manual...
  • Page 41: Ingress And Egress Control

    For example, if a port’s Ingress rate is set to 1000K and Egress rate is set to 100K. That means the device connected to this port is limited to 1000Kbps receiving (downstream) speed and 100Kbps sending speed (upstream). This AirLive SNMP-FSH2602MG User’s Manual...
  • Page 42 For example, a port that is connected to an ftp server can be set to allow Egress at maximum speed but Ingress at minimum rate. This will allow other people quickly download from the server, but restrict on upload. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 43: Trunking (Administrator Menu)

    In conclusion, Link aggregation lets you group up to eight consecutive ports into a single dedicated connection. This feature can expand bandwidth to a device on the network. LACP operation requires full-duplex mode, more detail information refers to IEEE 802.3ad AirLive SNMP-FSH2602MG User’s Manual...
  • Page 44: Aggregator Setting

    If LACP enable, you can configure LACP Active/Passive status in each port on State Activity page. Click Apply. Aggregator Information Clicking on the Aggregator Information will show the state of the aggregator. Three different screens can be shown to indicate the different status: AirLive SNMP-FSH2602MG User’s Manual...
  • Page 45: State Activity

    If the following page is shown, it indicates LACP trunking group has been made. State Activity Click on the State Activity will show which ports are working in trunking mode. User can also enable and disable LACP control from here. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 46: Filter Database (Administrator Menu)

    (Administrator menu) IGMP Snooping The SNMP-FSH2602MG supports multicast IP, one can enable IGMP protocol on web management’s switch setting advanced page, then display the IGMP snooping information in this page, you can view difference multicast group, VID and member port in here, IP multicast addresses range from 224.0.0.0 through 239.255.255.255.
  • Page 47: Static Mac Address

    When you add a static MAC address, it remains in the switch's address table, regardless of whether the device is physically connected to the switch. This saves the switch from having to re-learn a device's MAC address when the disconnected or powered-off device is active on the network again. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 48: Mac Filtering

    VLANs. Type the VID (tag-based VLANs) to associate with the MAC address. Click the Add. MAC filtering MAC address filtering allows the switch to drop unwanted traffic. Traffic is filtered based on the destination addresses. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 49: Vlan Configuration (Administrator Menu)

    Layer 2 switch. However, all the network devices are still plug into the same switch physically. The SNMP-FSH2602MG switch supports port-based, 802.1Q (tagged-based) and protocol-base VLAN in web management page. In the default configuration, VLAN support is disabled.
  • Page 50: Port-Based Vlan

    802.v protocol VLAN classification, it is possible to group VLAN by protocol through multiple switches SNMP-FSH2602MG will support protocol-based VLAN classification by means of both built-in knowledge of layer 2 packet formats used by selected popular protocols, such as Novell IPX and AppleTalk’s EtherTalk, and some degree of programmable protocol...
  • Page 51: Configuring Port Based Vlan

    VLAN groups. NOTE: If the trunk groups exist, you can see it (ex: TRK1, TRK2…) in select menu of ports, and you can configure it is the member of the VLAN or not. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 52: Configuring 802.1Q And 802.1V Vlan

    VLAN, VID is 1. The default VLAN can’t be deleted. Figure 4-18 Configure 802.1Q/V VLAN Basic Create a VLAN and add tagged member ports to it. From the main menu, click Administrator VLAN configuration, click Add then you will see the page as follow. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 53: Port Vid

    Uses this page to set the outgoing frames are VLAN-Tagged frames or no. Then click Apply. Tag: outgoing frames with VLAN-Tagged. Untag: outgoing frames without VLAN-Tagged. Port VID Configure port VID settings From the main Tag-based (IEEE 802.1Q) VLAN page, click Port VID Settings. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 54: Spanning Tree (Administrator Menu)

    VLAN but that don’t support tagging. Each port of SNMP-FSH2602MG allows user to set one PVID, the range is 1~255, default PVID is 1. The PVID must as same as the VLAN ID that the port belong to VLAN group, or the untagged traffic will be dropped.
  • Page 55: Setting Spanning Tree

    Spanning-Tree Protocol configuration messages before attempting a reconfiguration. Enter a number 6 through 40. You can change Hello time value, the number of seconds among the Hello Time transmission of Spanning-Tree Protocol configuration messages. Enter AirLive SNMP-FSH2602MG User’s Manual...
  • Page 56: Port Mirror (Administrator Menu)

    The Port Mirror is a method for monitor traffic in switched networks. Traffic through ports can be monitored by one specific port. That is, traffic goes in or out monitored ports will be duplicated into Analysis port. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 57: Snmp/Trap Manager (Administrator Menu)

    Fill in the system options data, and then click Apply to update the changes on this page. Name: Enter a name to be used for the switch. Location: Enter the location of the switch. Contact: Enter the name of a person or organization. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 58: Security Manager (Administrator Menu)

    If no trap manager is defined, no traps are issued. Create a trap manager by entering the IP address of the station and a community string. Security Manager (Administrator menu) On this page, user can change user name and password with following steps. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 59: Introduction To 802.1X Authentication Protocol

    Ethernet frame. On the diagram above, the PC on part 1 wants to access Internet service through the switch, it will need to get authorized by the authentication server on port 11 in order to gain access. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 60: Configuration (Administrator Menu)

    Hotspot provider: Wireless ISP installs Access Point in airport, café, and many public areas. They charge customer based on the usage. 802.1x gives service provider a feasible way for authentication. With the SNMP-FSH2602MG switch, the APs do not have to support 802.1x. The authenticator function will be handled by the switch.
  • Page 61: Per Port Configuration

    Au:The state of the specific port was determined by the outcome of the authentication. No:The specific port didn't support 802.1x function. Misc Configuration In this page, you can change the default configuration for the 802.1x standard: AirLive SNMP-FSH2602MG User’s Manual...
  • Page 62: Ping

    This switch provides a simplified ping function for user to check whether an IP is on line or not. Input the IP Address and counts of ping packet to send. Press “Apply” to continue next page AirLive SNMP-FSH2602MG User’s Manual...
  • Page 63: Tftp Update Firmware

    Find out what is the computer’s IP address. In web management select administrator—TFTP update firmware. Enter the computer IP address into the “TFPT Server IP Address” field Download new image.bin file by pressing <update firmware>. After update finished, press <reboot> to restart switch. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 64: Configuration Backup

    TFTP Backup Configuration Use this page to set TFTP server IP address. You can save current EEPROM value from here, then go to the TFTP restore configuration page to restore the eeprom value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 65: Reset System

    Press “Prev” or “Next” button will browse previous 25 or next 25 sequences. The “Top” button will re-list the table from the latest event. “Clear” button will clear all history. Event logger displays the real time according to the time zone where user is. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 66: Terminal Management

    Terminal Management The SNMP-FSH2602MG supports terminal management through Telnet or Console Port. Console Port management allows out-of-band management and serves as a backup when Web/Telnet management fails. For station that does not have Internet Explorer, users can use Telnet for in-band management. You will also learn how to manage the switch remotely through Internet on telnet.
  • Page 67: Figure 5-1 Manual Ip Setting

    This IP address must be on the same subnet as the switch but different from the switch’s IP. Please make sure the IP is not used by other network device. If the switch’s IP address is AirLive SNMP-FSH2602MG User’s Manual...
  • Page 68: Remote Management

    *Note2: If IP address of the switch is lost, please use console port management to find the switch’s IP address. *Note3: The SNMP-FSH2602MG has DHCP client ability. This allows DHCP server (or router) to assign IP automatically. However, we do not recommend turning on the DHCP client because the DHCP server assign the IP randomly.
  • Page 69: Telnet To The Switch

    Step 1: Open your telnet program Step 2: type “o <switch’s IP address> and press enter Step 3: When prompt for User’s name and Password, enter the following information: User’s Name: admin Password: AirLive SNMP-FSH2602MG User’s Manual...
  • Page 70: Console Port Management

    Making RS-232 Cable Connection to the Host PC The way to make a RS-232 cable connection is simple. Just prepare a proper RS-232 cable and, with it, connect the console port of your SNMP-FSH2602MG and the COM port (either COM1or COM2) of your host PC.
  • Page 71: Using Windows Hyperterminal

    Note: After you have established a RS-232 cable connection between SNMP-FSH2602MG and your host PC, if your SNMP-FSH2602MG or the host PC is not powered on, you should power them up before you can configure smart console functions. Using Windows HyperTerminal After you have properly established a RS-232 cable connection between the console port of SNMP-FSH2602MG and the host PC.
  • Page 72 Step 3: Ether any name you would like to have for this connection (in this example, we use SNMP-FSH2602MG as name for the connection) and choose an icon. Click OK. Step 4: The Connect to dialog box appear. Since the HyperTerminal connection is made through...
  • Page 73 The COM port properties dialog box (in this case, COM1 Properties dialog box) appears. Configure the various port settings such as followings: Bits per second: 57600 Data bits: 8 Parity: None Stop bits: 1 Flow Control: None Click OK. Step 6: Press <Enter> when the blank screen appears AirLive SNMP-FSH2602MG User’s Manual...
  • Page 74: Main Menu

    Step 7: When prompted for User’s name and password. Enter “admin” as username and “123” as password. After the host PC has successfully connected to SNMP-FSH2602MG, you will see the Switch Setup Main Menu appears. Main Menu Once getting into the terminal management main screen, the Telnet and Console Port management will share the same configuration method.
  • Page 75: Switch Configuration

    <Edit>: Configure all items. Finished configure press Ctrl+A: Back to action menu line. <Save>: Save all configure value. <Previous Page>: Return to previous page to configure. <Next page>: Go to the next page to configure it. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 76: Port Configuration

    Half: User can set half flow control function (backpressure) as enable or disable. NOTE: Pressing <Save> only can save one page configuration. If the static trunk groups exist, you can see it (ex: TRK1, TRK2…) after port 26, and you can configure all of the items as above. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 77: Trunk Configuration

    All ports in the same static trunk group will be treated as single port. So when you setting VLAN members and Port configuration they will be toggled on or off simultaneously. NOTE: If VLAN group exist, all of the members of static trunk group must be in same VLAN group. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 78: Vlan Configuration

    NOTE: Change the VLAN mode for every time, user have to restart the switch for valid value. If set 802.1Q VLAN, you can set PVID, ingress filtering 1 and ingress filtering 2 in this page too. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 79: Create A Vlan Group

    Member: Press <Space> key to choose VLAN member. There are two types to selected: Member:the port is member port. No:the port is NOT member port. Press Ctrl+A go back action menu line. Select <Save> to save all configure value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 80: Create 802.1Q Vlan

    Tagged:This port is the member port of this VLAN group and outgoing frames are VLAN-Tagged frames. NO:The port is NOT member of this VLAN group. Press Ctrl+A go back action menu line. Select <Save> to save all configure value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 81: Edit / Delete A Vlan Group

    Choose the VLAN group that you want to edit or delete and then press enter. User can modify the protocol VLAN item and the member ports are tagged or un-tagged and remove some member ports from this VLAN group. After edit VLAN, press <Save> key to save all configures value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 82: Groups Sorted Mode

    In this page, user can select VLAN groups sorted mode: sorted by name sorted by VID. The Edit/Delete a VLAN group page will display the result. In the Edit/Delete a VLAN Group page, the result of sorted by name. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 83 In the Edit/Delete a VLAN Group page, the result of sorted by VID. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 84: Misc Configuration

    Misc Configuration MAC Age Interval Type the number of seconds that an inactive MAC address remains in the switch’s address table. The valid range is 300~765 seconds. Default is 300 seconds. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 85: Broadcast Storm Filtering

    The valid range is 1~255ms. Default Max Delay Time is 255ms. NOTE: Make sure “Max bridge transit delay bound control” is enabled before enabling Low Queue Delay Bound, because Low Queue Delay Bound must be work under “Max bridge transit delay bound control” is enabled situation. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 86: Port Security

    MAC addresses screen to define a list of MAC addresses that can use the secure port. Actions-> Select <Edit>. Press Space key to choose enable / disable item. Press Ctrl+A to go back action menu line. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 87: Collision S Retry Forever

    Collisions Retry Forever: Disable – In half duplex, if happen collision will retry 48 times and then drop frame. Enable – In half duplex, if happen collision will retry forever (Default). Hash Algorithm Select CRC-Hash (default) or DirectMap for Hash algorithm AirLive SNMP-FSH2602MG User’s Manual...
  • Page 88: Ifg Compensation

    IFG Compensation Enable or disable the inter-frame gap (IFG) compensation function Administration Configuration AirLive SNMP-FSH2602MG User’s Manual...
  • Page 89: Change Username

    Change Username Use this page; user can change web management user name. Type the new user name, and then press <Save> item. Change Password Use this page; user can change web management login password. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 90: Device Information

    Device Information This page is provided to the user to configure the device information. IP Configuration User can configure the IP setting and fill in the new value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 91: Port Mirror Configuration

    Select <Save> to save all configure value. On the action menu line you can press <Next Page> to configure port9 ~ port26, press <Previous Page> return to last page. NOTE: Only has one sniffer mode in switch at the same time. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 92: Priority Configuration

    Priority Configuration Port Static Priority This static priority based on port, if you set the port is high priority, income frame from this port always high priority frame. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 93: 802.1P Priority Configuration

    Press Space key to select the priority level mapping to high or low queue. High/Low Queue Service Ration H:L: User can select the ratio of high priority packets and low priority packets. Press Ctrl+A go back action menu line. Select <Save> to save all configure value. MAC Address Configuration AirLive SNMP-FSH2602MG User’s Manual...
  • Page 94: Static Mac Address

    This saves the switch from having to re-learn a device's MAC address when the disconnected or powered-off device is active on the network again. In this page user can add / modify / delete a static MAC address. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 95 Then select <Save> to save all configure value. Edit static MAC address Press <Edit> key. Choose the MAC address that you want to modify and then press enter. Press <Edit> key to modify all the items. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 96 Press Ctrl +A to go back action menu line, and then select <Save> to save all configure value. Delete static MAC address Press <Delete> key. Choose the MAC address that you want to delete and then press enter. Pressing <Enter> once will complete deletion on delete mode. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 97: Filtering Mac Address

    Vlan ID: If tag-based (802.1Q) VLAN are set up on the switch, type the VID to associate with the MAC address. Press Ctrl+A to go back action menu line, and then select <Save> to save all configure value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 98 Choose the MAC address that you want to modify and then press enter. Press <Edit> key to modify all the items. Press Ctrl+A to go back action menu line, and then select <Save> to save all configure value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 99: Protocol Related Configuration

    Delete filter MAC address Press <Delete> key to delete a filter MAC address. Choose the MAC address that you want to delete and then press enter. When pressing <Enter> once will complete deletion on delete mode. Protocol Related Configuration AirLive SNMP-FSH2602MG User’s Manual...
  • Page 100: Stp Spanning Tree Protocol

    When STP enabled, to ensure that only one path at a time is active between any two nodes on the network. STP Enable This page is showed the users how to enable or disable Spanning Tree function. Press Space key to select enable or disable. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 101 You can view spanning tree information about the Root Bridge on the left. On the right, user can set new value for STP parameter. NOTE: All about the parameter description please see the sections Web configuration’s explanation of Spanning Tree. Perport Configuration AirLive SNMP-FSH2602MG User’s Manual...
  • Page 102: Snmp

    System Name: Type a name to be used for the switch. System Contact: Type the name of contact person or organization. System Location: Type the location of the switch. Press Ctrl+A go back action menu line. Press <Save> to save the configure value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 103 Write Access: Enable the rights is read only or read-write. Restricted: Read only, enables requests accompanied by this string to display MIB-object information. Unrestricted: Read write, enables requests accompanied by this string to display MIB-object information and to set MIB objects. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 104 Edit Community Name Press <Edit> key, choose the item that you want to modify and then press Enter. Community Name: Type the new name. Write Access: Press <Space> key to change the right is restricted or unrestricted. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 105: Trap Managers

    A trap manager is a management station that receives traps, the system alerts generated by the switch. If no trap manager is defined, no traps are issued. Create a trap manager by entering the IP address of the station and a community string. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 106 Press <Edit> key, and then choose the item that you want to modify. IP: Type the new IP address Community Name: Type the community name. Press Ctrl +A go to actions line, press <Save> key to save all configure. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 107: Gvrp

    Choose the trap manager that you want to delete and then press enter. When pressing <Enter> once will complete deletion on delete mode. GVRP GVRP (GARP [Generic Attribute Registration Protocol] VLAN Registration Protocol) GVRP allows automatic VLAN configuration between the switch and nodes. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 108: Igmp

    Press Ctrl+A back to action menu line. Select <Save> to save configure value. Note: GVRP must also be enabled on participating network nodes. IGMP The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 109: Lacp (Link Aggregation Control Protocol)

    Press Space key to choose Enabled / Disabled. Press Ctrl+A go back action menu line. Select <Save> to save configure value. LACP (Link Aggregation Control Protocol) This page can configure and view all the LACP status. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 110 Press Ctrl+A go back action menu line. Press <Save> to save the configure value. NOTE: If user set LACP mode in the trunk group, all of the member ports of this trunk group will set "Active" automatic. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 111 When you’re setting trunking group, you can see the relational information here. Static trunk group LACP trunk group <Quit>: Exit this page and return to previous menu. <Previous Page>: Return to previous page to view. <Next page>: Go to the next page to view. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 112: 802.1X Protocol

    802.1x Protocol This page can configure and view all the 802.1x status. 802.1x Enable 1.Select <Edit>. 2.Press Space key to choose Enabled / Disabled. 3.Press Ctrl+A go back action menu line. 4.Select <Save> to save configure value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 113 4. NAS, Identifier: A string used to identify this switch. 5. Server Port: The UDP port number used by the authentication server to authenticate. 6.Accounting Port: The UDP port number used by the authentication server to retrieve accounting information. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 114: X Perport Configuration

    Fu:Force the specific port to be unauthorized. Fa:Force the specific port to be authorized. Au:The state of the specific port was determined by the outcome of the authentication. No:The specific port didn't support 802.1x function. 802.1x Misc Configuration AirLive SNMP-FSH2602MG User’s Manual...
  • Page 115 (Default value is 2 times). Reauth Period: Used to determine a nonzero number of seconds between periodic re-authentication of the supplications (Default value is 3600 seconds). Press Ctrl+A go back action menu line. Press <Save> to save configuration value. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 116: Status And Counters

    OutRate: Display the output rate control (100K/unit) setting value. Enabled: Display the port is enabled or disable depended on user setting. Enable will be display “Yes”, disable will be display “No”. If the port is unlink will be treated as “No”. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 117: Port Counters

    Module 1 Type: Display the module 1 type :1000Tx or 100Fx ext. Depend on module card mode. Module 1 information: Display the information saved in eeprom of module1. Module 2 Type: Display the module 2 type :1000Tx or 100Fx ext. Depend on module card mode. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 118: Reboot Switch

    Module 2 information: Display the information saved in eeprom of module2. Reboot Switch Default Reset switch to default configuration. Restart Reboot the switch in software reset. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 119: Tftp Update Firmware

    TFTP Server: Type the IP of TFTP server. Remote File Name: Type the image file name. Press Ctrl+A go to action line. Press <Save> key, it will start to download the image file. When save successfully, the image file download finished too. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 120: Restore Configure File

    Remote File Name: Type the image file name. Press Ctrl+A go to action line. Press <Save> key, it will start to download the image file. When save successfully, the image file download finished too. Restart switch. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 121: Backup Configure File

    Remote File Name: Type the image file name. Press Ctrl+A go to action line. Press <Save> key, it will start to upload the image file. When save successfully, the image file upload finished too. Restart switch. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 122: Application Examples

    Internet access, that are used by all the stations connected to the different Segmented Ports. Virtual LAN, or VLAN, is generally defined as broadcast domain. It can be viewed as a group of end nodes, possibly on different physical network segments, which can communicate with each other AirLive SNMP-FSH2602MG User’s Manual...
  • Page 123: Benefit Of Vans

    Below is a example that R&D, Manufacturing and Administration group can be partitioned into two different VLAN group, even members in different group can’t talk directly, but they still share the same server, such as MRP server, printer server in Administration group…etc. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 124: Trunking Application Used With Switch

    AirLive SNMP-FSH2602MG User’s Manual...
  • Page 125 Moreover, a remote administrator can access the far-side servers in the private domain through the intermediary of single IP switch which is directly connected to internet. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 126 Administrator (192.168.223.30) can access those slaves through master LAN IP: 192.168.223.254 IP: 192.168.223.30 WAN IP: 211.23.53.250 Switch IP: 192.168.223.100 Agent IP: 192.168.223.100 Gateway: 192.168.223.254 Switch IP: 192.168.223.101 Gateway: 192.168.223.254 Switch IP: 192.168.223.102 Gateway: 192.168.223.254 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 127 According to the basic rule 1, agent IP should be set in the same domain of slaves, that is, 192.168.223.100. The other procedures are the same as example 1. Now administrator (192.168.1.30) can access the slaves in other domain (192.168.223.0). AirLive SNMP-FSH2602MG User’s Manual...
  • Page 128 Somewhat we can image the master is playing a role of tiny virtual server for these slaves. LAN IP: 192.168.223.254 WAN IP: 211.23.53.250 Gateway IP: 192.168.223.249 Switch IP: 192.168.223.101 Gateway: 192.168.223.254 Switch IP: 211.23.53.251 Agent IP: 192.168.223.100 Gateway: 211.23.53.249 Switch IP: 192.168.223.102 Gateway: 192.168.223.254 AirLive SNMP-FSH2602MG User’s Manual...
  • Page 129 (e.g. tag-based VLAN groups) and link status among all stacked units. A typical arrangement of network connection of “Single IP – Stacking mode” is shown below: Typical connections for switch management by stacking AirLive SNMP-FSH2602MG User’s Manual...
  • Page 130 IP and agent IP should be kept as the same as the LAN IP exactly. 3. Add stacking members in the Stacking management. Please refer section 2-4-14 for detailed configuration. 4. Launch the Stack manager. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 131 Slave4 (192.168.223.140) Port 23, 24 of Slave5 (192.168.223.150) Test case: 1. PC-0 ping or trace PC-01 and PC-02 (The same VLAN ) 2. Remove port 9 of Slave4 from VLAN test, and process test1 again. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 132 Result: 1. PC-0 can access both PC-01 and PC-02. AirLive SNMP-FSH2602MG User’s Manual...
  • Page 133 2. PC-0 can only access PC-02 only. PC-01 will not reply AirLive SNMP-FSH2602MG User’s Manual...
  • Page 134: Appendix A Product Specifications

    19" inch rack mountable • Standard Compliance IEEE 802.3 10BaseT Ethernet IEEE 802.3u 100BaseTX Fast Ethernet IEEE 802.3ab 1000Base-T Gigabit Ethernet over Cat.5 cable IEEE 802.3z 1000BaseSX/LX Fiber Gigabit Ethernet IEEE 802.3x flow control IEEE 802.1d Spanning Tree AirLive SNMP-FSH2602MG User’s Manual...
  • Page 135 802.1v protocol-based VLAN classification Supporting Protocols: IP, ARP, AppleTalk, AppleTalk AARP, Novell IPX, Banyan Vines, DECnet MOP, DECnet DPR, DECnet, LAT, DECnet LAVC, IBM SNA, X.75 Internet, X.25 Layer 3 GVRP Auto VLAN Configuration IP Multicast AirLive SNMP-FSH2602MG User’s Manual...
  • Page 136 Power Built-in Power Supply Input: 90-260VAC, 50/60Hz Consumption: 36 Watts max. • Dimension 440mm (W) X 184mm (D) X 44mm (H) • Weight 2 KG • Regulation FCC Part 15 Class A CE mark, Class A AirLive SNMP-FSH2602MG User’s Manual...
  • Page 137: Appendix B Troubleshooting

    • If you find out where the problem is but cannot solve it by yourself, or you simply cannot locate what is at fault, please contact your local dealer for technical support. AirLive SNMP-FSH2602MG User’s Manual...

Table of Contents