Maintenance

Your Vent Free Heater will provide years of service with
minimal upkeep. The following procedures will help
ensure that your stove continues to perform safely and
efficiently.

Firebox Cleaning and Inspection

Cleanliness is critical to correct operation of the heater.
The log set, burner, valve controls and air circulation
areas must all be kept free of dust and unobstructed by
debris. Inspect these areas before each use and clean
whenever accumulation is evident. Follow the simple
procedure outlined below.
Frequent cleaning may be necessary in living
environments subject to excessive carpet lint or pet
hair. For example, if you live with a dog that sheds
continuously, you will need to inspect the burner area
frequently and clean it as often as the accumulation
requires. In extreme conditions, it may be necessary to
clean the burner and log set monthly or bi-weekly.
This appliance should be inspected and thor-
oughly cleaned annually by a qualified gas techni-
cian.

Cleaning Procedure

1. Turn the burner OFF and let the heater cool com-
pletely before cleaning.
2. Freestanding or Hearthmount: Lift the Front Plate up
and then swing the bottom out to disengage from
heater shell. (Fig. 16)
3. Remove the safety screen by swinging the cam
latches on the frame outward. (Fig. 29)
4. Carefully inspect the log set for damage. Contact
your local dealer if any damage is evident. DO NOT
OPERATE THE HEATER WITH A DAMAGED LOG
SET.
5. Use a soft-bristled brush vacuum attachment to
sweep dust or debris from the log set, pilot and
burner. Use care as the log set is fragile.
6. Replace the screen and Front Plate. DO NOT
OPERATE THE HEATER WITH THE SAFETY
SCREEN REMOVED.
16

Care of Cast Iron

An occasional dusting with a dry rag will help keep the
painted surfaces looking new.
Porcelain enamel surfaces shoul be cleaned with a soft
damp cloth. Do not use abrasive cleaning agents. If
necessary, use only a cleaning agent formulated
specifically for use on porcelain enamel surfaces.
Cam Latches
Fig. 29 Swing Cam Latch to free screen frame and remove
away from unit.
W A R N I N G
DUST AND DEBRIS ACCUMULATION CAN
RESULT IN POOR PERFORMANCE. INSPECT
THE VALVE COMPARTMENT, BURNER PARTS
AND LOG SET FREQUENTLY AND CLEAN
THESE PARTS MONTHLY OR AS OFTEN AS
ACCUMULATION WARRANTS.
ST119