1. Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).
2. Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo
button, light a match and hold the flame to the end of the pilot and ignite the pilot.
. After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot
access.
4. Call a qualified service technician for repair or replacement of the piezo ignitor.
Turn off heater and allow to cool before
cleaning.
Disconnect electrical power (optional
blower) before cleaning or servicing.

MAINTENANCE

Remove logs carefully by holding gently at each end.
Gloves are recommended to prevent skin irritation from
ceramic fibers. If skin becomes irritated, wash gently with
soap and water. Refer to Log Placement, Pages 15-17 for
correct log placement.
PERIODIC CLEANING
gram for location of items discussed below.
Do not use cleaning fluid to clean logs or any part of
heater.
Brush logs with soft bristle brush or vacuum with
brush attachment.
Vacuum loose particles and dust from the front and
rear burner, control and piezo covers and grate weld-
ment.
Inspect and clean burner air intake holes. Remove
lint or particles with vacuum, brush, or pipe cleaners.
Failure to keep air intake holes clean will result in
sooting and poor combustion.
External case should be dusted and wiped with a
wet soapy cloth.
22

MATCH LIGHTING INSTRUCTIONS

- Refer to the parts dia-
OPERATING INSTRUCTIONS and MAINTENANCE
ANNUAL CLEANING/INSPECTION
the parts diagram for location of items discussed
below.
Inspect and clean burner air intake holes. Remove
lint or particles with vacuum, brush or pipe cleaners.
Failure to keep air intake holes clean will result in
sooting and poor combustion.
Inspect and clean all burner ports.
Inspect ODS pilot for operation and accumulation of
lint at air intake holes.
Verify flame pattern and log placement for proper
operation.
Verify smooth and responsive ignition of main burner
and rear burner.
- Refer to