Da-Lite ASCENDER ELECTROL Instruction Book page 4

Table of Contents

Advertisement

ASCENDER ELECTROL
WARNING: To prevent electrical shock or damage to the low voltage control (LVC), do not apply power to the LVC until all
connections are complete. Make sure power is turned off on all wires before making connections.
Wall Switch
1. Install wall switch where desired.
2. Use 2-conductor 20-24 gauge wire to extend the switch wire to the required length.
3. Connect the wire from the switch to the wire labeled "wall switch" . Refer to figure 3.
CAUTION: Never apply voltage to the wall switch lead or the LVC will be damaged.
Control Panel
A control panel may be connected to the LVC by using the wall switch wire lead. The control panel must provide a
momentary, dry contact closure of at least 1/2 second.
1. Use 2-conductor 20-24 gauge wire to connect the control panel to the wall switch lead.
2. A momentary closure when the screen is down will be an "up" command.
3. A momentary closure when the screen is fully extended will be a "down" command.
4. A momentary closure while the screen is in motion will be a "stop" command.
CAUTION: Never apply voltage to the wall switch lead or the LVC will be damaged.
AC Power Source
1. Refer to figure 3 for electrical connections. Wiring designated as external is to be completed by installer
conforming to local and national codes.
NOTE: Must be installed in accordance with the requirements of the Local Building Codes, the Canadian Electrical Code (CEC),
CAN/CSA C22.1 and the National Electric Code (NEC), NFPA 70. An appropriate disconnect device shall be provided as part of
the building installation.
2. Use 14-18 gauge wire to connect power to the LVC wires labeled "AC power input" . Refer to figure 3.
3. Connect the building ground wire to the ground lug on the metal housing.
Radio Frequency Remote
1. Remove the center cover plate of the LVC box.
2. Route the receiver wire through the round plastic bushing and plug it into the onboard socket marked "EYE" . Refer
to figure 3.
Infrared Remote
1. Remove the center cover plate of the LVC box.
2. Route the receiver wire through the round plastic bushing and plug it into the onboard socket marked "EYE" . Refer
to figure 3.
INSTALLATION
®
LOW VOLTAGE CONNECTIONS:
120V/240V CONNECTIONS:
OPTIONAL WIRELESS REMOTE CONNECTIONS: