Da-Lite ADVANTAGE ELECTROL Instruction Book
Hide thumbs Also See for ADVANTAGE ELECTROL:

Advertisement

Quick Links

The Da-Lite Difference.
DA-LITE SCREEN COMPANY, INC.
Instruction Book for
3100 North Detroit Street
Post Office Box 137
AdvAntAge® electrol®
Warsaw, Indiana 46581-0137
Phone: 574-267-8101
800-622-3737
Fax: 574-267-7804
Toll Free Fax: 877-325-4832
www.da-lite.com
e-mail: info@da-lite.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVANTAGE ELECTROL and is the answer not in the manual?

Questions and answers

Summary of Contents for Da-Lite ADVANTAGE ELECTROL

  • Page 1 The Da-Lite Difference. DA-LITE SCREEN COMPANY, INC. Instruction Book for 3100 North Detroit Street Post Office Box 137 AdvAntAge® electrol® Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737 Fax: 574-267-7804 Toll Free Fax: 877-325-4832 www.da-lite.com e-mail: info@da-lite.com...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS When using your video equipment, basic safety precautions should always be followed, including the following: 1. Read and understand all instructions before using. 2. Position the cord so that it will not be tripped over, pulled, or contact hot surfaces. 3.
  • Page 3 ADVANTAGE ELECTROL INSTALLATION ® ® 6-1/16" 6-7/16" VARIABLE POSITION 7-3/4" MOUNTING BRACKET MOTOR END 8" AUDIENCE SIDE 6-1/16" 3/8" THREADED ROD (NOT INCLUDED) ATTACHED TO ELECTRICAL MOUNTING BRACKET JUNCTION BOX 6-3/8" SELF-TRIMMING FINISHED FLANGE CEILING 7-3/4" SEE DETAIL A 3.41" 3/8"...
  • Page 4 ADVANTAGE ELECTROL INSTALLATION FOR 120V SCREENS ® ® 120V WIRING DIAGRAM FOR STANDARD WALL SWITCH JUNCTION BOX LOCATED IN WHITE LEFT ENDCAP MOTOR BLACK GREEN NOTE: A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN ONE SCREEN. CONTACT THE FACTORY FOR FURTHER INFORMATION.
  • Page 5: Important Note

    ADVANTAGE ELECTROL INSTALLATION FOR 120V SCREENS ® ® RJ-14 PIN-OUTS RJ-22 PIN-OUTS 120V WIRING DIAGRAM (TAB IS FACING UP) (TAB IS FACING UP) WITH OPTIONAL BUILT-IN +12V BLUE BUS (RP DATA) WHITE BUS (RP DATA) YELLOW LOW VOLTAGE CONTROL RQ DATA GREEN RQ DATA GREEN...
  • Page 6: Wall Switch

    240VOLT AC/ 50HZ 240 VOLT WIRING DIAGRAM FOR STANDARD POWER SOURCE WALL SWITCH: GREEN/YELLOW (GROUND) Da-Lite offers two styles of 240 volt wall switches for standard operation. Please see wiring diagram included in wall switch box included with screen. BLACK WHITE...
  • Page 7 Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at Da-Lite. Should it be necessary to adjust for more or less drop of picture, proceed in the following manner: Remove two screws to remove access door.
  • Page 8: Stop Button

    SCREEN ADJUSTMENT FOR 120V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL OR VPI 1. Locate the wall switch and remove the cover plate from the 3-button wall switch and remove the switch from the junction box. 2. Locate the two tactile buttons on the back of the switch. They are square silver with black round buttons. See Figure 4 (VPI) or Figure 5 (LVC) for diagram.
  • Page 9: Troubleshooting

    TROUBLESHOOTING SYMPTOM CAUSE SOLUTION 1. Screen will not operate. (a) Incorrect line voltage. (a) Verify 115-125V (or 220-240V). If insufficient voltage, rewire Motor does not hum. incoming electric line. (b) Blown fuse. (b) Replace fuse. (c) Tripped circuit breaker. (c) Reset circuit breaker. (d) No power to operating switch (d) Check above.
  • Page 12 FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF  EQUIPMENT, OR FOR INCIDENTAL, DIRECT, OR CONSEQUENTIAL DAMAGES OF ANY  NATURE. In the event that there is a defect in materials or workmanship of a Da-Lite product, you may contact our Sales Partners at PO Box 137 , Warsaw, IN 46581-0137 , (574) 267-8101, (800) 622-3737 . IMPORTANT: THIS WARRANTY SHALL NOT BE VALID AND DA-LITE SHALL NOT BE ...

Table of Contents