What To Do If - Electrolux EIW63810X User Manual

Refreshment centre
Table of Contents

Advertisement

18 electrolux

What to do if...

Warning All repairs should be carried out by authorised technicians
Problem
Cold sparkling water sprays
CO₂ gas
Water is not dispensed
Small ice shards
Low carbonation level
No cold water, no shards
available 3 hours after starting
the appliance
Cold still water sprays CO₂ gas Carbonating system
Six LEDs alarm troubleshooting
All operations below require for the
appliance to be switched on and
extracted from cabinet.
Pull out the Refreshment Centre and
proceed as follows
• Check water supply
• Check water inlet pressure
• Check CO₂ pressure
• Water leakage check
• Cold restart
If none of the procedures turns off the
alarm or resolve your problem, close the
inlet water and call the Assistance.
Check water supply
Check if the tap between the water mains
and the water inlet hose is open or water
is coming out from other taps in the house.
When water comes out and the water
mains work properly, proceed with the
step Check water inlet pressure.
If your water mains connection does not
work properly, please have it checked.
Cause
Carbonator limit reached
No water supply
Inlet water low pressure
No water supply
Low pressure of inlet water
Low CO₂ pressure
Brand new appliance
After a week
Cooling system
Check water inlet pressure
Pressure can be checked using the water
pressure reducer with gauge.
Pressure has to be regulated between 2
and 3 bar.
Check CO₂ pressure
Please check the gauge while dispensing
cold sparkling water.
Pressure has to be regulated 0.5 bar
above inlet water value operating on the
CO₂ plastic knob.
Water leakage check
Stop the dispensing and wait 20
seconds, then start dispensing
again
Check water supply
Check water inlet pressure
Check water supply
Check water inlet pressure
Check CO₂ pressure
Use for 1 week
Call technical assistance
Call technical assistance
Call technical assistance
Warning It is recommended to check
the CO₂ pressure value when
changing the water inlet pressure
For further information see the
chapter on first installation.
Warning Never exceed the indicated
inlet value
For further information see the
chapter on first installation.
Warning If water covers the whole
base, please turn off the appliance,
close the inlet water and call the
Assistance.
Resolution

Advertisement

Table of Contents
loading

Table of Contents