Night Set Mode - Daikin FTXN09KEVJU Service Manual

Inverter pair wall mounted type k-series
Hide thumbs Also See for FTXN09KEVJU:
Table of Contents

Advertisement

Main Functions
1.8

NIGHT SET Mode

Outline
When the OFF timer is set, the NIGHT SET Mode is automatically activated. The NIGHT SET
Mode keeps the airflow rate setting.
Detail
The NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in the
case of heating. This prevents excessive cooling in summer and excessive heating in winter to
ensure comfortable sleeping conditions, and also conserves electricity.
<Cooling>
09/12 class
15/18/24 class
<Heating>
28
Target temperature
TIMER operation
NIGHT SET Mode ON
Target temperature
TIMER operation
NIGHT SET Mode ON
(A) : When the outdoor temperature is normal and the room
temperature is at the set temperature.
(B) : When the outdoor temperature is high (27˚C (80.6˚F) or higher).
Target temperature
TIMER operation
NIGHT SET Mode ON
0.5˚C (0.9˚F)
1 hour
+0.5˚C (+0.9˚F)
temperature shift
0.5˚C (0.9˚F)
1 hour
30 minutes
+0.5˚C (+0.9˚F)
temperature shift
1 hour later
Operation stops
at the set hours
(A)
0.5˚C (0.9˚F)
(B)
Operation stops
at the set hours
(A) +0.5˚C (+0.9˚F) temperature shift
(B)
Target temperature remains the same
2˚C (3.6˚F)
(R14454)
Function and Control
SiUS041111
(R14453)
(R14662)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents