Removal Of Electrical Box / Vertical Blades - Daikin FTXN09KEVJU Service Manual

Inverter pair wall mounted type k-series
Hide thumbs Also See for FTXN09KEVJU:
Table of Contents

Advertisement

Indoor Unit: 09/12 Class
1.5

Removal of Electrical Box / Vertical Blades

Procedure
Step
1. Disconnect the connecting
wires.
1
Remove the screw of
the service cover.
2
Pull out the service
cover down in the
direction of the arrow.
3
The figure shows the
connections of wire
harnesses.
4
Remove the screw of
the wire retaining plate.
134
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Terminal board
Indoor heat exchanger thermistor
Service cover
(R14676)
(R11636)
Electrical box
Wire retaining plate
(R11637)
(R11638)
SiUS041111
Points
Preparation
 Remove the front grille
according to the "Removal of
Front Grille".
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading