Power Supply Waveforms Check; Electronic Expansion Valve Check - Daikin FTXN09KEVJU Service Manual

Inverter pair wall mounted type k-series
Hide thumbs Also See for FTXN09KEVJU:
Table of Contents

Advertisement

Check
5.3

Power Supply Waveforms Check

Check No.11
Measure the power supply waveform between No. 1 and No. 2 on the terminal board, and check
the waveform disturbance.
 Check to see if the power supply waveform is a sine wave. (Fig.1)
 Check to see if there is waveform disturbance near the zero cross. (sections circled in Fig.2)
Fig.1
5.4

Electronic Expansion Valve Check

Check No.12
Conduct the followings to check the electronic expansion valve (EV).
1. Check to see if the EV connector is correctly connected to the PCB.
2. Turn the power off and on again, and check to see if the EV generate latching sound.
3. If the EV does not generate latching sound in the above step 2, disconnect the connector and
4. Check the continuity between the pins 1 - 6, 2 - 6, 3 - 6, 4 - 6. If there is no continuity between
5. If the continuity is confirmed in the above step 3, the outdoor unit PCB is faulty.
Note:
Please note that the latching sound varies depending on the valve type.
118
check the continuity using a tester.
the pins, the EV coil is faulty.
Fig.2
Harness 5P
(5)
S20
Check
6P Connector
1 2 3 4 5 6
6-1
6-2
6-3
6-4
(R14245)
Service Diagnosis