2. Enter the frequency of the ripple control signals of your local power utility, or of
the interharmonics which are to be monitored. Five different channels
(frequencies) are possible.

Sequential Logging Jobs

The 1744/1743 and 1745 Power Quality Loggers can handle two measurement jobs of the
same type (both P or both A) in sequence: While one measurement job is active, the setup
data of the previous jobs are temporarily retained in the memory. You can check the
"running" or "complete" status of these jobs anytime by selecting
Menu>Logger>Information about Logger. Clicking the Info button
also allows you to check the job status.
Logger name
Date/time
Retrieving the data will not influence the logging job. The Logger will
continuously record interval and event data during the data transfer and
the active job will not be aborted.
Figure 15. Set up Logger for Function A
Note
PC Software for 1740 Series
Advanced (Optional) Logger Settings
egd013a.bmp
on the tool bar