Hyper Terminal Setup - HIKVISION DS-630XDI Series User Manual

Decoder server
Table of Contents

Advertisement

Description:
This chapter is about the network parameters configuration of Hikvision DS-630XDI Decoder.
The DS-630XDI factory default user name is admin, password is 12345.
The DS-630XDI factory default IP address is 192.0.0.64.
The network parameters need to be setup before the decoding channel configuration. The network parameters are
used to connect with the software which is applied to set the decoding channels. The network parameters are
including IP address, subnet mask, gateway and port.

3.1 Hyper Terminal Setup

The common method is to connect decoder and PC with serial line, run Hyper Terminal and modify parameters
with serial command. Please connect the RS-232 port of decoder with the COM port of PC directly, power on the
decoder and PC and follow the steps:
Step1: Enter Hyper Terminal.
Click "Start"-> "Programs"->"Accessories"-> "Communications"->"Hyper Terminal" in Windows system, and the
dialogue box below will appear as Figure 3.1.1.
Figure 3.1.1
Step2: Name the connection and define the icon.
Input a name (e.g. HK), select an icon, and press "OK" to enter "Connect To" dialogue box.
Step3: Select the communication port.
Select "COM1" in "Connect To" interface (Please select the COM port according to the reality, in case PC has
more than 1 COM.). Press "OK" to enter "Properties" dialogue box.