40) QR code print
ESC + "q" + S + E + M + DATA [+ "," + M + DATA +......] + NUL
HEX CODE <1B>h + <71>h + S + E + M + DATA [+ <2C>h + M + DATA +....] + <00>h
About parameter
1.
S: module size
* Assign 1 module size of QR code by printer's dot numbers.
* There are 5 sizes which can be assigned, 1, 2, 3, 4, 8 dots
* If invalid size is assigned, the printer assigns it as 4 dots
2. E: Correction level
* Selects error correction level to be used for restoring QR symbol.
* Following values can be assigned.
* If invalid value is assigned, the printer determines it to be L.
3. M: Input data mode
* Assign input data mode
* Following modes can be assigned
* If invalid mode is assigned, data is ignored until valid
Mode is assigned.
* If multiple modes should be input, each mode data (M + data) needs to be
separated by " , ".
* If you want to input " , " and NULL in the data of 8 bit byte mode, input " ! "
<21>h+"," and " ! "<21> h + NULL.
* " ! " itself is input as " ! " + " ! "
* Kanji data should be input by Shift JIS code.
Restrictions
Available QR codes are from version 1 to version 14 of model 1 symbols.
If input data exceeds the area to be printed, QR code is not printed.
:<<ESC q S E M>>
E
Correction level
0
L
1
M
2
Q
3
H
M
Input data mode
"N"
Numeric mode
"A"
Alpha numeric mode
"B"
8 bit byte mode
"K"
Kanji mode
Restore. capability
7%
15%
25%
30%