Conettix D6600/D6100i | Installation and Operation Guide | 11.0 Network Communications

11.0 Network Communications

References to the Network Ethernet
Module model number are defined in the
Installation Supplement.
Refer to the appropriate Installation
Supplement included with your product
for the specifics of your particular
installation.
The Conettix D6600 and D6100i Communications
Receiver/Gateway systems support data network
communications. This allows the receiver to connect
to Ethernet networks, and process messages to and
from most networks in user datagram protocol (UDP)
or internet protocol (IP). Use a COM4 or a COM1
connection from the D6600 to connect the Network
Ethernet Module to the network. The D6100i has a
built-in Ethernet module that can connect directly to
the network. Refer to Conettix D6600/D6100i Network
System Guide (P/N: 4998122712) for configuration
setup instructions. Central station automation
software, through a local-area network (LAN) or wide-
area network (WAN), receives reports from alarm
control panels from the PSTN or other data networks.
The automation software also monitors the control
panel status and connection over the network. Update
or upgrade the receiver through the network
connection. Use the D6200 software for remote
programming of the receiver. Refer to the following
documents about network communications and their
installation requirements.
Conettix D6600/D6100i Network System Guide
(P/N: 4998122712)
D9133TTL-E Installation Guide
(P/N: 4998122717)
C900V2 Installation Guide (P/N : F01U003472)
C900TTL-E Installation Guide (P/N: 4998122718)
DX4020 Installation Guide (P/N: F01U045288)
D6680 Ethernet Network Adapter Installation
Guide (P/N: 4998138732)
DeviceInstaller Operation and Installation Guide
(P/N: 4998138688)
24
Figure 14: Conettix Network System
Connection Diagram - C900TTL-
E/C900V2 and Any Control Panel
2
3
1
P A N E L
1 2 3
4 5 6
7 8 9 1 0
O
F F
T E L C O
15
11
14
12
1 – Any manufacturer's control panel
2 – Connection - Control panel telco jack to
C900TTL-E jack
3 – C900TTL-E/C900V2 Dialer Capture Module
4 – Connection - C900TTL-E/C900V2 Ethernet
jack to Ethernet hub
5 – Host PC running D6200 Programming
Administrative Software
6 – Connection - Host PC network interface card
(NIC) to Ethernet hub
7 – Ethernet hub
8 - Connection – Ethernet hub to D6100i
9 - D6100i
10 – Connection – Ethernet hub to Network
Ethernet Module
11 – Network Ethernet Module
12 – Connection – Network Ethernet Module to
D6600 COM4 port
13 – D6600
14 – Connection – Second Network Ethernet
Module to D6600 COM 1 port (optional)
15 – Connection – Ethernet hub to second Network
Ethernet Module
Bosch Security Systems, Inc. | 6/09 | 4998122704-06
4
5
6
7
8
10
9
11
13