Locked Link Mode - Single Imager

If you link an imager to a base using the Locked Link Mode, other imagers are
blocked from being linked if they are inadvertently placed into the base. If you
do place a different imager into the base, it will charge the imager, but the imager
will not be linked.
To use a different imager, you need to unlink the original imager by scanning the
Unlink Imager bar code. (See

Open Link Mode - Single Imager

When newly shipped or defaulted to factory settings, the base and imager are not
linked. By placing an imager into the base, they establish a link. Placing a
different imager into the base establishes a new link and the old imager is
unlinked. Each time an imager is placed into the base, it becomes the linked
imager; the old imager is unlinked.

Override Locked Imager

If you need to replace a broken or lost imager that is linked to a base, scan the
Override Locked Imager bar code below with a new imager and place that imager
in the base. The locked link will be overridden; the broken or lost imager's link
with the base will be removed, and the new imager will be linked.