Imager Orientation
When the IT4X00 Series is mounted with the label pointing up, captured images appear right side up.
Connector Position and Flex Orientation
Connector
The interface connector is a Molex 0.30mm (.012") Easy-On™ Type Right Angle, SMT, ZIF, Bottom Contact Style Receptacle
part number 54393-2192. See
Connector Pinout
Pin
Signal
1
Ground
2
LED Current Control PWM
3
Ground
4
Horizontal Sync (H Data Valid)
5
Vertical Sync (V Data Valid)
6
Aimer On
7
Illumination On
8
Power Enable
9
2
I
C Data (SDA)
10
2
I
C Clock (SCL)
IMAGETEAM™ 4X00 Series Integration Manual
Flex
Interface Connector
on page 1-2 for details.
Description
Power and signal ground.
Input - Controls the LED current. A pulse width modulated signal based on a frequency of 7.5K Hz
reduces the current of the LED power supply. The relationship of current to duty cycle is inversely pro-
portional (the longer the duty cycle, the lower the current). Leave this pin unconnected if not using this
feature.
Power and signal ground.
Output - Definition varies according to the setting of the image registers. For the configuration defined in
this document, this signal is used as a data valid window. Polarity of this signal is selectable in register
address 0x01, Bit 1. Hand Held Products setting is 1 = active high window.
Output - Definition varies according to the setting of the image registers. For the configuration defined in
this document, this signal is used as a data valid window. Polarity of this signal is selectable in register
address 0x01, Bit 2. Hand Held Products setting is 0 = active low window.
Input - Active high on this line enables the LED power supply and turns on the 2 aiming LEDs. This line
may be pulse width modulated many times per horizontal line (based on pixel clock) in order to reduce
power.
Input - Active high on this line enables the LED power supply and turns on the 4 illumination LEDs. This
line may be pulse width modulated many times per horizontal line (based on pixel clock) in order to
reduce power.
Input - Active high enables the imager. A low on this line places the imager in a power down state.
Imager follows slave protocols with respect to this signal.
Imager follows slave protocols with respect to this signal.
Top